background image

 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
 
 
 
 

PHIRE

 

Fiber Adapters For Camera Link 

 

User Manual 

Revision 4 

 

PHx-xx-Mxxx, PHx-xx-Sxx 

PHR-6x-M025-E 

 

TM

 

D-A-CH

Laser 2000 GmbH
82234 Wessling
Tel. +49 8153 405-0
[email protected]
www.laser2000.de

FrAnCe – Telecom

Laser 2000 SAS
78860 St-N. l. Bretèche 
Tel. +33 1 30 80 00 60 
[email protected]
www.laser2000.fr 

FrAnCe – Photonic

Laser 2000 SAS
33600 Pessac 
Tel. +33 5 57 10 92 80 
[email protected]
www.laser2000.fr

IberIA

Laser 2000 SAS
28034 Madrid
Tel. +34 617 308 236
[email protected]
www.laser2000.es 

norDICs

Laser 2000 GmbH
112 51 Stockholm
Tel. +46 8 555 36 235
[email protected]
www.laser2000.se

Содержание PHRONTIER PHIRE PHR-68-M025

Страница 1: ...France Telecom Laser 2000 SAS 78860 St N l Bretèche Tel 33 1 30 80 00 60 info laser2000 fr www laser2000 fr France Photonic Laser 2000 SAS 33600 Pessac Tel 33 5 57 10 92 80 info laser2000 fr www laser2000 fr Iberia Laser 2000 SAS 28034 Madrid Tel 34 617 308 236 info laser2000 es www laser2000 es Nordics Laser 2000 GmbH 112 51 Stockholm Tel 46 8 555 36 235 info laser2000 se www laser2000 se ...

Страница 2: ...ct Safety and Regulatory Compliance 12 8 1 Product Safety 12 8 2 Regulatory Compliance 12 9 Contact Us 13 FIGURES Figure 1 PHIRETM System Diagram 5 Figure 2 Electrical Connection of DC Input Connector Front View 6 Figure 3 Optical fiber connection 8 TABLES Table 1 Installation and Power up Steps for the PHIRE System 5 Table 2 PoCL features and pin assignment on MDR26 plug 7 Table 3 LED Functionali...

Страница 3: ...erent applications customized options available 2 Available Models 2 1 Two fiber models with multimode fibers Model PHR 68 M025 PHR 85 M025 PHR 85 M020 Image Data a 24 bit 16 bit 24 bit Pixel Clock 68 MHz 85 MHz 85 MHz Distance OM3 fiber 600 m 1800 ft 600 m 1800 ft 550 m 1650 ft OM2 fiber 250 m 900 ft 250 m 900 ft 200 m 700 ft OM1 fiber 150 m 450 ft 150 m 450 ft 100 m 300 ft PHR 6x M025 E for 20 7...

Страница 4: ...r Users would need the following items for proper installation To ensure safe and successful installation of the PHIRE system into your application we STRONGLY RECOMMEND that you power off all related electronic devices including the camera frame grabber and PHIRE CM PHIRE FG modules BEFORE performing the following installation Otherwise system malfunction may happen and DAMAGE may be caused to th...

Страница 5: ...d secure the module with thumb screws 3 Plug PHIRE FG module to the frame grabber and secure the module with thumb screws 4 Take off the caps on LC connectors at both ends of optical fiber cable Take off the caps on the LC fiber ports of PHIRE CM and PHIRE FG Plug LC fiber cable to both PHIRE CM and PHIRE FG Users should hear a click sound which indicates a successful mate 5 Connect power plugs to...

Страница 6: ...atible with the Base configuration specified in the Camera Link standard which consists of up to 24 bit of image data FVAL LVAL DVAL SP CC1 CC2 CC3 CC4 and a bi directional serial port Figure 1 The exact bit assignment is defined in Appendix C of the Camera Link standard PHx 68 supports max 24 bit of image data with up to 68MHz of pixel clock rate PHx 85 supports up to 24 bit of image data with up...

Страница 7: ...e you have the correct fiber cable before testing the units For more information about the fiber cable please see paragraph 5 5 of this manual The PHIRE system you have purchased is designed to accept both multimode and single mode SFP transceivers This unique feature provides users with more flexibility and a cost effective solution to apply the same PHIRE system to different applications that re...

Страница 8: ...mally specify the type of fiber on the outer jacket of the cable Otherwise users need to verify with the manufacturers The OM3 fiber is in aqua or light blue color It is newly deployed for 10Gbit Ethernet applications All three types of MM fibers can be used with Phrontier fiber extenders However the maximum transmission distances will vary with the use of different type of MM fibers Please refer ...

Страница 9: ...width 2 Gb s 2 Gb s 2 5 Gb s Connector Type MDR26 plug 6 2 2 Single fiber models PHIRE S series Models a PHx 68 M50 PHx 68 S10 PHx 85 M50 PHx 85 S10 PHx 85 M25 PHx 85 S07 Max Pixel Clock 68 MHz 85 MHz 85 MHz Max Image Data Width 24 bits 16 bits 24 bits Transport Bandwidth 2 Gb s 2 Gb s 2 5 Gb s Connector Type MDR26 plug a X L for LC connectors X S for SC connectors D A CH Laser 2000 GmbH 82234 Wes...

Страница 10: ...50nm FG Min Optical Tx Output Power 3 9 dBm 3 9 dBm 3 10 dBm 3 8 dBm Min Optical Rx Power 15 dBm 15 dBm 18 dBm 16 dBm Connector Type SC or LC simplex Fiber Type 50 125 µm or 62 5 125 µm MM fibers 9 125 µm SM fibers a X L for LC connectors X S for SC connectors 6 4 Mechanical Dimensions No Mounting Brackets D A CH Laser 2000 GmbH 82234 Wessling Tel 49 8153 405 0 info laser2000 de www laser2000 de F...

Страница 11: ... CM connection 4 ON OFF Blink OFF a Camera malfunction after PHIRE initialized b Insecure PHIRE CM connection after initialization a Inspect secure PHIRE CM connection b Reset camera and PHIRE system 5 OFF OFF Blink Blink a PHIRE CM no power b Fuse burn off on the CM module possible causes including current or voltage surge from direct DC power on or due to improper electrical grounding a Check PH...

Страница 12: ...nctions normally but no clear image a Incompatible camera and frame grabber a Test system compatibility before installing PHIRE Table 4 Trouble Shooting Procedures 8 Product Safety and Regulatory Compliance 8 1 Product Safety The fiber optical adaptors are designed and categorized as a Class 1 Laser product ALWAYS avoid viewing directly into the optical ports as the laser will cause serious damage...

Страница 13: ...r all other inquiries info phrontier tech com Mail US Office Phrontier Technologies LLC 26471 Rancho Parkway South STE A Lake Forest CA 92630 USA D A CH Laser 2000 GmbH 82234 Wessling Tel 49 8153 405 0 info laser2000 de www laser2000 de France Telecom Laser 2000 SAS 78860 St N l Bretèche Tel 33 1 30 80 00 60 info laser2000 fr www laser2000 fr France Photonic Laser 2000 SAS 33600 Pessac Tel 33 5 57...

Отзывы: