Extraordinary maintenance log
Extraordinary maintenance
⚠
The following table is for logging any extraordinary maintenance jobs, repairs and improvements performed
by specialized contractors.
⚠
Any extraordinary maintenance jobs must be done only by specialized technicians.
Fitter's stamp
Name of operator
Job performed on (date)
Technician's signature
Requester's signature
Job performed _______________________________________________________
__________________________________________________________________
___________________________________________________________________
Malfunctions
What to do
The operator neither opens nor closes
1-2-4-14
1 Check the power supply and line fuses
2 The N.O. control contact (2-7) is open
3 The N.C. safety contact (2-C1) is open
4 The N.C. safety contacts are open
5 Check in menu 7 that a time is set
6 Check the proper direction of the door travel
7 Memorize the radio code again
8 Adjust the sensitivity in menu 4
9 Eliminate all mechanical friction
10 Enter (or duplicate) the same code in all
the transmitters
11 Check operation of the photocells
12 Check door balancing
13 Check the belt/chain tautness
14 Encoder malfunction: cut off and power up
again the control board
The operator opens but does not close
3-6-12
The operator closes but does not open
12
The operator does not perform the automatic closing
5-6
The transmitter does not work
7
The operator is too powerful
8
The operator is too weak
8-9-12-13
The operator inverts the travel direction
8-9-12-13
Only one transmitter works
10
The photocells do not work
3-11
The POWER on signal LED is off
1-2
The operator inverts the travel direction at the limit
switch
6-9-12
The operator starts too slowly
9-12-13
TROUBLESHOOTING
Fitter's stamp
Name of operator
Job performed on (date)
Technician's signature
Requester's signature
Job performed ________________________________________________________
__________________________________________________________________
___________________________________________________________________