The ENTER key is for:
- entering menus;
- confi rming or memorizing set values.

The ESC button is for:
- exiting menus;
- cancelling changes.

The < > keys are for:
- moving from one item to another;
- increasing or decreasing values.

Display

To enter the menu, keep the 
ENTER button pressed for at 
least one second.

To select menu items, use 
the arrow keys ...

... then press ENTER

also for the submenus, use 
the arrow keys to select ...

To increase or decrease a 
value, use the arrow keys ...

... to exit the menu, wait 10 
seconds or press ESC.

 When the menu is active, the system cannot be used.

... the press ENTER to 
confi rm ...

... then press ENTER

Description of programming commands

Browsing the menu

Содержание SDN4

Страница 1: ...BXV Installation manual SDN4 SDN6 SDN8 SDN10 OPERATOR FOR SLIDING GATES FA00014 EN English EN...

Страница 2: ...N BE CAREFUL WHEN HANDLING GEARMOTORS THAT WEIGH OVER 20 KG IF NEED BE USE PROPER SAFETY HOISTING EQUIPMENT ALL OPENING COMMANDS THAT IS BUTTONS KEY SWITCHES MAGNETIC READERS AND SO ON MUST BE INSTALL...

Страница 3: ...R OPERATION TO PREVENT POTENTIALLY HAZARDOUS SITUATIONS READ THE INSTRUCTIONS IF THE POWER SUPPLY CABLE IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER OR AUTHORIZED TECHNICAL ASSISTANCE SERVICE OR...

Страница 4: ...l management systems This product complies with the current regulations mentioned in the declaration of conformity DESCRIPTION Operator complete with control board movement control and obstruction det...

Страница 5: ...USE INTENSIVE USE INTENSIVE USE INTENSIVE USE Operating temperature C 20 55 20 55 20 55 20 55 Thrust N 350 600 800 1000 Maneuvering speed m min 12 12 11 11 Weight Kg 10 10 5 11 5 11 7 Description of p...

Страница 6: ...re is are opening and closing mechanical gate stops make sure that the point where the gearmotor is fastened is protected from any impacts and that the surface is solid enough make sure you have set u...

Страница 7: ...ovisions of regulation CEI EN 60204 1 For multiple sequential loads along the same line the dimensions on the table need to be recalculated according to the actual power draw and distances For connect...

Страница 8: ...n frame to reinforce the concrete Fit the bolts into the anchoring plate and lock them using the washers and nuts Remove the pre shaped clamps using a screw driver or pliers If the rack is already the...

Страница 9: ...the gearmotor above the anchoring plate Careful The electric cables must pass under the gearmotor case Remove the nut and washer from the bolts Fit the electric cables into the tubes so that they com...

Страница 10: ...motor see RELEASING THE GEARMOTOR paragraph rest the rack above the gearmotor pinion weld or fasten the rack to the gate along its entire length To assemble the rack modules use an extra piece and res...

Страница 11: ...sting fasten the gearmotor to the plate using the washers and nuts Establishing the limit switch points For opening open the gate t the opening limit switch n onto the rack until the micro switch acti...

Страница 12: ...tions are quick fuse protected Fuses ZN7 Line 1 6 A F Accessories 2 A F Description of parts 1 Terminal for gearmotors 2 Terminals for encoders 3 Terminals for limit switches 4 Command and safety devi...

Страница 13: ...Green Brown White Factory wiring Opening limit switch NC contact Closing limit switch NC contact 230 V AC 50 60 Hz 24 V AC DC control board power supply input 24 V AC DC max 40 W accessories power sup...

Страница 14: ...Alternatively from the functions programming you can activate the single command OPEN STOP CLOSE STOP sequential See function F7 To be able to snap in the cards into the dedicated connectors remove t...

Страница 15: ...opening the contact triggers the inversion of movement until the gate is fully closed If contacts CX and CY are not used they should be deactivated during programming Safety devices Photocells Con gur...

Страница 16: ...ignaled on display E4 Enable function F5 in programming See the PAIRED CONNECTION WITH SINGLE CONTROL chapter Connection for paired operation and for CRP Came Remote Protocol Fit the RSE card Rio Wire...

Страница 17: ...he keys are for moving from one item to another increasing or decreasing values Display To enter the menu keep the ENTER button pressed for at least one second To select menu items use the arrow keys...

Страница 18: ...speed F 30 Adjusting opening slow down speed F 34 Sensitivity during movement F 35 Sensitivity during slow down F 36 Adjusting partial opening F 37 Adjusting the gearmotor s opening slow down starting...

Страница 19: ...Activated The gate opens and closes by keeping the button pressed Opening button on contact 2 3P and closing button on contact 2 7 All other control devices even radio based ones are excluded F7 Comm...

Страница 20: ...er outage F20 Automatic closing time after a partial opening 0 Deactivated 1 1 second 10 seconds default 180 180 seconds The wait before the automatic closing starts after a partial opening command fo...

Страница 21: ...mode 0 Deactivated default 1 Activated Uploading settings from Master to Slave This appears only if function F49 is set to Paired F54 Opening direction 0 Opening towards the left default 1 Opening to...

Страница 22: ...ns for an adjustable time of between 5 seconds and 40 seconds This function only appears if the Encoder function is deactivated U 1 Entering a user 1 Step step command open close 2 Sequential command...

Страница 23: ...to associate to the user The commands are step step open close 1 sequential open stop close stop 2 open 3 partial opening 4 Press ENTER to con rm User Associated command 1 2 3 4 5 6 7 8 9 10 11 12 13...

Страница 24: ...ver until it reaches a nal stop Travel calibration Before calibrating the gate travel position the gate half way check that the maneuvering area is clear of any obstruction and check that there are me...

Страница 25: ...tic closing time on the SLAVE operator s control panel Configuring the MASTER operator Select function F 49 Press ENTER to con rm Select 1 paired and press ENTER Perform settings and adjustments on th...

Страница 26: ...ctrical connections are done and the set up is nished fasten the cables to the gearmotor jumper using a cable tie Fit the cover and fasten it to the sides using the screws RELEASING THE GEARMOTOR This...

Страница 27: ...oes not close The photocells are dirty Clean and check proper functioning of the photocells TROUBLESHOOTING MAINTENANCE Periodic maintenance Before any maintenance job cut off the mains power supply t...

Страница 28: ...its premises which is compliant with the UNI EN ISO 14001 standard to ensure the environment is safeguarded Please continue safeguarding the environment At CAME we consider it one of the fundamentals...

Отзывы: