SETTINGS

DOOR SAFETY CHECK

CALIBRATION

IMPORTANT

: Test the good 

functioning of the installation 
before leaving the premises.

If necessary, position spots 
closer to or away from the door 
and 

relaunch a calibration

.

After changing a DIP-switch, the orange LED flashes. 

A LONG push on the push button of the 

MASTER

 

confirms the settings of ALL MODULES.

Afterwards, a number of green flashes (x) indicates 

the number of connected modules.

A SHORT push on the button of the 

MASTER

 launches a 

calibration on ALL MODULES.

Do not stand in the detection field!

When the LED is off on all modules, the detection zone is OK.

The detection zone is too short: 

turn the screw clockwise.

The detection zone is too long: 

turn the screw anticlockwise.

Step out of the detection field. 

If necessary, change angle or switch off background (DIP 3 = OFF).

Launch a new calibration. 

The flashing speed of 
the LED increases when 
approaching the optimal 
position.

MOUNTING

 SIDE

FREQUENCY

BACKGROUND

UNCOVERED 

ZONE

RELAY 1

STOP

RELAY 2

REOPENING

FREQ A

FREQ B

ON

OFF

HIGH*

LOW

ON

OFF

LED during detection:

R1 > RED

R2 > GREEN

Set different 

frequencies on 

modules close to 

each other.

Not enough background 

reflectivity: switch to OFF

Approximate values at 2 m:

high= 40 cm, low = 15 cm

RED-GREEN

OFF

GREEN

RED

ORANGE

ORANGE

GREEN

OFF

FACTORY VALUE

* Recommended for most applications.

Mounting height > 2.7 m: set to LOW for 

EN 16005 and DIN 18650-conformity.