background image

P

age 

30

 - Manual 

FA01384-EN

  - 03/2021 - © C

AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T

ranslation of the o

riginal instructions

New user

Register up to a maximum of 250 users and assign a function to each one.

 The operation can be carried out by using a transmitter or another control device. The boards that manage the control devices (AF - R700 - R800) must 

be inserted into the connectors.

U1

New user

1 = Step-by-step
2 = Sequential
3 = Open
4 = Partial opening
When the barrier is in [Paired] mode, the [Partial opening] command opens the Master 
barrier.

Choose the function to be assigned to the user.
Press ENTER to confirm.
You will be asked to enter your user code.
Send the code from the control device.
Repeat the procedure to add other users.

Remove user

Remove one of the registered users.

U2

Remove user

OFF (Default)
ON
Use the arrows to choose the number associated with the user you want to remove.
No. 1 > 250
Alternatively, the control device associated with the user you want to remove can be 
activated.
Press ENTER to confirm.

Remove all

Remove all registered users.

U3

Remove all

OFF (Default)
ON

Radio decoding

Choose the type of radio coding for the transmitters enabled to control the operator.

 If you choose the type of radio coding for the transmitters [Rolling code] or [TW key block], any transmitters with a different type of radio coding saved 

previously will be deleted.

U4

Radio decoding

1 = All (Default)
2 = Rolling code
3 = TW key block

Self-Learning Rolling

Save a new transmitter by activating acquisition from a remote control that has already been saved (see the remote control manual).

U8

Self-Learning Rolling

OFF (Default)
ON

Boom length

Set the boom length.

A1

Boom length

3 = 3 m boom
4 = 4 m boom
6 = 6 m boom
8 = 8 m boom

Содержание GGT80AGS

Страница 1: ...Automatic road barriers GGT80AGS GGT80RGS GGT80ACS GGT80AX4 GGT80AX6 INSTALLATION MANUAL FA01384 EN EN English...

Страница 2: ...the result of an accident or installation error In these cases the tensioned springs no longer guarantee that the boom is balanced The boom may suddenly rotate when being released Manual release may...

Страница 3: ...th the installation rules It should completely cut off the power supply according to category III surcharge conditions Demarcate the entire site properly to prevent unauthorised personnel from enterin...

Страница 4: ...uidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling Before dismantling and disposing of the produc...

Страница 5: ...ainted galvanised steel cabinet accessories available Balance springs included Intended use Ideal solution for apartment blocks and industrial applications Any installation and or use other than that...

Страница 6: ...ing cover 6 Photocell holes 7 Lock for release 8 Cabinet 9 Inspection hatch 10 Inspection hatch lock 11 Control panel 12 Safety microswitch with cover open 13 Mechanical stop for the boom adjustment 1...

Страница 7: ...inal board associated with the RSE_2 connector for CRP connection IO 485 card or Modbus RTU interface 13 Terminal board for connecting the electric lock 14 Terminal board for connecting the safety mic...

Страница 8: ...an indoor environment use cables with properties at least equivalent to those of type H05VV F designation to 60227 IEC 53 If the cable lengths differ from those specified in the table define the cable...

Страница 9: ...ened in place Preliminary operations If the flooring does not allow the device to be fastened in a solid and stable way lay a cement slab Dig a hole for the foundation frame Set up the corrugated tube...

Страница 10: ...otice Translation of the original instructions Fill the hole with soil around the concrete block Remove the nuts from the screws Thread the electrical cables into the tubes so that they protrude by ab...

Страница 11: ...Page 11 Manual FA01384 EN 03 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions Changing the boom opening direction...

Страница 12: ...l may be changed at any time and without notice Translation of the original instructions Boom installation Insert the reinforcement inside the boom First install the LED strip where applicable ONLY TH...

Страница 13: ...s to the same size as the boom slot minus 10 millimetres 2 Insert the slot cover profiles into the grooves on both sides of the boom 3 Insert the anti impact rubber profile into the groove 4 Cut off t...

Страница 14: ...h LED strip and full height skirt A A A A B B B B Boom with LED strip and swing rest A B A A A A A A A A Boom with LED strip single skirt and swing rest A A A A A A Boom with LED strip full height ski...

Страница 15: ...riginal instructions Assembling the balance spring 1 Release the gearmotor 2 Position the boom vertically 3 Lock the gearmotor 4 5 6 Assemble the anchoring pin and fix it on the lever arm 7 Tighten th...

Страница 16: ...otor 2 Manually turn the spring to increase or reduce the traction The boom should stabilise at 45 Where there are two springs carry out the procedure on both springs at the same time 3 Fasten the loc...

Страница 17: ...with mechanical limit switches Check that the boom is parallel to the road surface when it is in the closed position and at about 89 when it is in the open position Correct the boom s horizontal posi...

Страница 18: ...time and without notice Translation of the original instructions Correct the boom s vertical position Release the gearmotor Open the inspection hatch 1 Turn the mechanical stop until you reach the des...

Страница 19: ...isconnected during all installation procedures Before working on the control panel disconnect the mains power supply and remove the batteries if any Connecting to the electrical network F Line fuse L...

Страница 20: ...address on each device the function of each accessory can be configured on the control panel This method allows you to configure the set up immediately without having to do so later and intervene dire...

Страница 21: ...2 Control device NO contact OPEN ONLY function When the HOLD TO RUN function is active the control device must be connected during OPENING 3 Control device NO contact PARTIAL OPENING function The cont...

Страница 22: ...If the red LEDs are flashing quickly the inspection hatch is open the gearmotor is released or the boom has dropped away 10 11 E1 TS 1 2 3 3P 4 5 7 2 CX CY CZ R G 1 3 Safety devices Connect the safet...

Страница 23: ...pairs can be connected See function F5 Safety devices test 10 11 E1 TS 1 2 3 3P 4 5 7 2 CX CY CZ 10 2 TX C NC TX 2 RX TX 10 11 E1 TS 1 2 3 3P 4 5 7 2 CX CY CZ 10 2 TX C NC TX 2 RX TX DXR DLX photocell...

Страница 24: ...nd qualified staff may perform this operation Check the warning and safety devices are working properly Make sure that there are no obstacles in the way Power up and proceed with the operations indica...

Страница 25: ...osure at the travel end during opening C7 Reopen while closing sensitive edges C9 Immediate closure at the travel end during opening with obstacle standby during closure C10 Immediate closure during o...

Страница 26: ...safety devices detect an obstacle The function activates with closed boom open boom or after a complete stop F9 Obstacle with motor stopped OFF Default ON Open warning light Barrier status warning Dev...

Страница 27: ...safety devices are triggered when an obstacle is detected after a complete stop during a power outage or if there is an error F19 Automatic closure OFF Default From 1 to 180 seconds Pre flashing time...

Страница 28: ...ions from the memory device memory roll or USB key The function is displayed only when a USB stick is inserted into the USB port or when a memory roll card is inserted into the control board F51 Read...

Страница 29: ...t while opening or closing the FCA CM1 or FCC CM2 contact closes and remains closed 3 Custom The FCA CM1 contact is closed with the boom in the open travel end position and during the opening manoeuvr...

Страница 30: ...user Remove one of the registered users U2 Remove user OFF Default ON Use the arrows to choose the number associated with the user you want to remove No 1 250 Alternatively the control device associa...

Страница 31: ...anoeuvre counter View the number of manoeuvres performed by the operator 1 1000 manoeuvres A5 Manoeuvre counter tot total manoeuvres PAr partial manoeuvres FW version Display the firmware version numb...

Страница 32: ...e standby during closure NO contact C13 Reopen while closing with immediate stop once the obstruction has been removed even if the gate is not in motion C23 Open command C24 Close command Import expor...

Страница 33: ...Page 33 Manual FA01384 EN 03 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions FINAL OPERATIONS...

Страница 34: ...essories must be connected to the control board which will be set as the MASTER RSE A B GND S1 GND A B GND UTP CAT 5 max 1000 m RSE A B GND S1 GND A B GND Programming All programming operations descri...

Страница 35: ...ector Connect up the electrics for the devices and accessories For information on connecting the electrics for the devices and accessories please see the ELECTRICAL CONNECTIONS section The control and...

Страница 36: ...21 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions 2 ONLY OPEN command 2 3 on barrier B 3 OPEN CLOSE command 2 7 on barrie...

Страница 37: ...t catalogue If the barrier with an articulated joint is used check that the moving parts of the joint are in good condition Replace them if necessary Every 250 000 cycles and in any case every 6 month...

Страница 38: ...1 Calibration error E3 Encoder failure error E4 Service test failure error E7 Operating time error E8 Open release hatch error E9 Obstacle detected during closing E10 Obstacle detected during opening...

Страница 39: ...Page 39 Manual FA01384 EN 03 2021 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions...

Страница 40: ...AME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy...

Отзывы: