F31 Closing slow-down speed
15 = Minimum speed / … / 40 = Maximum speed
Setting the boom's closing slow-down speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary depending on the type of boom:
- for jointed booms of 2 m, set the slow-down speed percentage to between 20 and 40;
- for booms of 4 m, set the slow-down speed percentage to between 20 and 30;
- for booms of 6 m, set the slow-down speed percentage to between 15 and 30;
- for booms of 8 m, set the slow-down speed percentage to between 15 and 20;
F33 Calibration speed
20 = 20% of the travel (minimum) / … / 40 = 40% of the travel (maximum)
Setting the boom's travel automatic calibration, calculated as a percentage
F34 Boom travel sensitivity
10 = maximum sensitivity / … / 100 = minimum sensitivity (
default
)
Adjusting obstruction detection sensitivity during boom travel.
F35 Slow-down sensitivity
10 = maximum sensitivity / … / 100 = minimum sensitivity (
default
)
Adjusting obstruction detection sensitivity during slow-down.
F37 Opening slow-down
point
40 = 40% of the travel / … / 60 = 60% travel
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down point.
Warning! The percentage varies depending on the boom type:
- for jointed booms of 2 m and 4 m, set the percentage to between 40 and 60;
- for booms of 6 m and 8 m, set the percentage to between 60 and 70.
F38 Closing slow-down point
20 = 20% of the travel /… / 75 = 75% of the travel
Establishing the total travel percentage, from the beginning of the closing slow-down point.
Warning! The percentage varies depending on the boom type:
- for jointed booms and 2-meter booms, set the speed percentage to between 20 and 40;
- for 2 m booms, set the percentage to between 40 and 60;
- for 6 m booms, set the percentage to between 60 and 70;
- for 8 m booms, set the percentage to between 65 and 75;
F49
0 = Deactivated (
default
) / 1 = Paired/ 2 = Alternating / 3 = CRP
For enabling the paired or alternate function or the CRP home automation connection system .
F50 Save data
0 = Deactivated (
default
) / 1 = Activated
Saving users and saved settings in memory roll.
This feature only appears if a memory roll has been fi tted into the control board.
F51 Read data
0 = Deactivated (
default
) / 1 = Activated
Uploading data saved in memory roll.
This feature only appears if a memory roll has been fi tted into the control board.
F52 Passing settings in
paired/alternating mode
0 = Deactivated (
default
) / 1 = Activated
Loading parameters of the MASTER barrier into the SLAVE barrier.
This function appears only if function F 49 is set to either PAIRED or ALTERNATE.
F56 Peripheral number
1 ----> 225
With systems fitted with several operators and the CRP (Came Remote Protocol) system connection, set an address between 1 and 225 for
each control panel.
F60 Sleep Mode
0 = Deactivated (
default
) / 1 = Activated
To enable a reduction in energy consumption when in stand-by.
F61 Pre-fl ashing
0 = when opening and closing (
default
) / 1 = when closing only / 2 = when opening only
After an opening or closing command, the fl ashing light connected to 10-E1m fl ashes before starting the maneuver.
For setting the time, see function F 21.
F63 Change COM speed
0=1200 Baud / 1=2400 / 2=4800 / 3=9600 / 4=14400 / 5=19200 / 6=38400 / 7=57600 / 8=115200 Baud
Setting the communication speed used in the CRP (Came Remote Protocol) connection system.
U 1 Entering a user
1 = Step-step command (open-close) / 3 = Open only command / 4 = partial/pedestrian opening command
(for either paired or alternate systems) / 5 = output B1-B2
Entering up to up to a 25 users maximum and associating to each one a function chosen among the existing ones. This must be done via
transmitter or other control device (see "ENTERING USERS WITH ASSOCIATED COMMAND paragraph).
U 2 Deleting a user
Deleting a single user
U 3 Deleting users
0 = Deactivated / 1 = Deleting all users
Deleting all users.
Содержание G4040EZT
Страница 1: ...English EN Русский RU Italiano IT Français FR FA00583M04 BARRIERE AUTOMATICHE ...
Страница 33: ...English EN INSTALLATION MANUAL G4040EZT AUTOMATIC BARRIERS FA00583 EN ...
Страница 65: ...Français FR MANUEL D INSTALLATION G4040EZT BARRIÈRES AUTOMATIQUES FA00583 FR ...
Страница 97: ...Русский RU ИНСТРУКЦИЯ ПО МОНТАЖУ G4040EZT АВТОМАТИЧЕСКИЕ ДОРОЖНЫЕ ШЛАГБАУМЫ FA00583 RU ...