Page
5
- Manual
FA01560-EN
- 02/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the original instructions
PRODUCT DATA AND INFORMATION
Key
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues.
This symbol shows what to tell users.
The measurements, unless otherwise stated, are in millimetres.
When the device is in operation, some mechanical parts are hot and may cause burns.
Description
G4000
Barrier made of painted galvanized steel designed to fit accessories.
G4001
Barrier made of AISI 304 satin-finish steel, designed to fit accessories.
G4000N
Barrier made of grey painted galvanized steel designed to fit accessories.
G40001-316
Barrier with cabinet made from satin-finished AISI 316 steel designed to fit accessories.
G4000X
Barrier made of galvanized steel with customised RAL paint designed to fit accessories.
G4010
Barrier made of painted galvanized steel set up to fit accessories. The barrier includes balance springs (1 x 001G04060).
G4010X
Barrier made of galvanized steel with customised RAL paint designed to fit accessories.
Intended use
Ideal solution for apartment blocks and industrial use.
Any installation and/or use other than that specified in this manual is forbidden.
Usage limitations
MODELS
G4000
G4001
G4000N
G40001-316
G4000X
G4010
G4010X
Max. net clearance width (m)
4
4
4
4
4
4
4
Technical data
MODELS
G4000
G4001
G4000N
G40001-316
G4000X
G4010
G4010X
Power supply (V - 50/60 Hz)
230 AC
230 AC
230 AC
230 AC
230 AC
120 AC
120 AC
Motor power supply (V)
24 DC
24 DC
24 DC
24 DC
24 DC
24 DC
24 DC
Power (W)
300
300
300
300
300
300
300
Current draw (A)
15 Max.
15 Max.
15 Max.
15 Max.
15 Max.
15 Max.
15 Max.
Colour
2004
-
7043
-
RAL X
2004
RAL X
Operating temperature (°C)
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
Storage temperature (°C)*
-25 ÷ +45
-25 ÷ +45
-25 ÷ +45
-25 ÷ +45
-25 ÷ +45
-25 ÷ +45
-25 ÷ +45
Torque (Nm)
200
200
200
200
200
200
200
Opening time at 90° (s)
3 ÷ 6
3 ÷ 6
3 ÷ 6
3 ÷ 6
3 ÷ 6
3 ÷ 6
3 ÷ 6
Duty cycle (%)
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
Protection rating (IP)
54
54
54
54
54
54
54
Insulation class
I
I
I
I
I
I
I
Average life (cycles)**
1.000.000
1.000.000
1.000.000
1.000.000
1.000.000
1.000.000
1.000.000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has
been installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including
significantly, by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product
warranty.
Fuse table
MODELS
G4000
G4001
G4000N
G40001-316
G4000X
G4010
G4010X
Line fuse
1.6 A-F
1.6 A-F
1.6 A-F
1.6 A-F
1.6 A-F
3.15 A-F
3.15 A-F
Accessory fuse
2 A-F
2 A-F
2 A-F
2 A-F
2 A-F
2 A-F
2 A-F
Control board fuse
1 A-F
1 A-F
1 A-F
1 A-F
1 A-F
1 A-F
1 A-F