GENERAL INSTRUCTIONS FOR INSTALLING

Installation must be carried out by expert qualified personnel and in full compliance with the regulations in force.

Important! Using original CAME control and safety devices and accessories ensures easy installation and system maintenance.

Preliminary checks

 Before beginning, do the following::

• make sure the plate is anchored to a solid spot;
• make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation rules. It should 
completely cut off the power supply according to category III surcharge conditions (that is, with minimum contact openings of 3 mm);
•   make sure that any connections inside the case (that provide continuance to the protective circuit) are fitted with extra insulation as compared 
to the other conductive parts inside;
• set up suitable tubes and conduits for the electric cables to pass through, making sure they are protected from any mechanical damage.

Tools and materials

Make sure you have all the tools and materials you need for installation at hand to work in complete safety and compliance with the current 
regulations. The following figure shows some basic equipment needed by the installer.

Connection

Cable type

Cable length

1 < 15 m

Cable length

15 < 30 m 

Power supply 230 V AC

H05RN-F

3G x 1.5 mm2

3G x 2.5 mm2

Flashing light

FROR CEI 

20-22 

CEI EN 

50267-2-1

2 x 0,5 mm2

-

Photocell transmitters

2 x 0,5 mm2

Photocell receivers

4 x 0,5 mm2

Command and safety device

2 x 0,5 mm2

Antenna

RG58

max 10 m

Metal mass detector

(see product literature)

 

If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected 

devices and according to the provisions of regulation CEI EN 60204-1.
For connections that require several, sequential loads, the sizes given in the table must be re-evaluated based on actual power draw and distances. 
When connecting products that are not specified in this manual, please refer to the documentation provided with said products.

Types of cable and minimum sizes

Содержание G3750

Страница 1: ...G3750 Street barriers EN English FA01237 EN INSTALLATION MANUAL...

Страница 2: ...using non original products which would result in warranty loss All maintained action commands must be fitted in places from which the moving barrier and transit and driving areas are visible Apply if...

Страница 3: ...ORDERING THE ILLUSTRATIONS IN THIS MANUAL ARE ALL FOR LEFT HAND BARRIERS Intended use The barrier is designed for use in private and public parking facilities in residential settings and for high rat...

Страница 4: ...m attachment cover 4 Anti shearing protective cover 5 Gearmotor release with customized key 6 Hatch lock with customized key 7 Gearmotor 8 Control panel 9 Balancing spring 10 Inspection hatch Standard...

Страница 5: ...r the electric cables to pass through making sure they are protected from any mechanical damage Tools and materials Make sure you have all the tools and materials you need for installation at hand to...

Страница 6: ...it the barrier and accessories will vary depending on the area where it is installed It is up to the installer to find the most suitable solution Caution Warning Use hoisting equipment to transport an...

Страница 7: ...he electric cables into the tubes so that they come out about 600 mm Place the plate over the iron cage Fill the foundation frame with concrete The base must be perfectly level with the bolts which ar...

Страница 8: ...arrier RIGHT barrier Entry side Internal zone Entry side Internal zone The cabinet should be installed with the inspection hatch on the most accessible side to make any adjusting easier Place the cabi...

Страница 9: ...me and without notice Original instructions Fit the shock resistant frame to the boom s lower side Fit the boom into the boom attaching cover and fasten it using the screws Note to mount with the G040...

Страница 10: ...nge at any time and without notice Original instructions Cut the groove profiles to length and fit them into the boom s groove Perform this procedure on both ends Fit the cap onto the end of the boom...

Страница 11: ...080 55 mm springs BOOM COMPOSITION m 1 5 to 1 75 1 75 to 2 25 2 25 to 2 75 2 75 to 3 25 3 25 to 3 5 3 5 to 3 75 Boom with shock proof profile A A A B B C Boom with shock proof profile and 001G028401 l...

Страница 12: ...nge at any time and without notice Original instructions Screw the spring onto the anchoring pin hooked onto the transmission arm Hook the eyelet rod on the spring onto the anchoring bracket Release t...

Страница 13: ...r again Note check the proper working state of the spring with the boom raised vertically the spring is not taut with the boom lowered horizontally the spring is taut Warning After performing balancin...

Страница 14: ...protected FUSE TABLE ZL38 Line 3 15 A F Card 630 mA F Gearmotor 10 A F Accessories 2 A F Main component parts 1 Accessories fuse 2 Line fuse 3 Control panel fuse 4 Motor fuse 5 Accessories terminals...

Страница 15: ...ng devices Warning light when barrier arm is open contact voltage rating 24V 3W max Warns that the barrier arm is open Flashing light and luminous cord contact voltage rating 24V 23 W max Both flash o...

Страница 16: ...comply with EN 12978 regulations C1 reopening while closing When the boom is closing opening the contact causes its movement to invert until fully opened If unused shortcircuit contact 2 C1 C5 immedi...

Страница 17: ...nsmitter you wish to memorize The LED stays lit to confirm that the transmitter is now memorized PROG key Programming LED Programming LED Establishing the endstop points The boom s opening and closing...

Страница 18: ...any time and without notice Original instructions To correct the horizontal position closing raise the bar adjust the mechanical closing stop and secure it with the counter nut Mechanical closing sto...

Страница 19: ...adjusted to between 1 and 120 seconds Trimmer adjustments Default settings Programming the features DIP SWITCH Description of functions 1 ON AUTOMATIC CLOSING 1 OFF deactivated 2 ON ONLY OPEN from bu...

Страница 20: ...is operation is potentially hazardous for users when for whatever reason such as the boom being badly fastened ripped out or broken during an accident and so on the loosened springs no longer provide...

Страница 21: ...uctions Establish the Master barrier and the Slave barrier On the MASTER barrier s electronic board make the necessary electrical connections activate the radio control program the functions and setti...

Страница 22: ...he opening endstop The warning LED flashes quickly 4 10 Check the closing endstop The warning LED stays lit 13 11 Activate the AUTOMATIC CLOSING function The boom does not reach the endstop 7 12 Check...

Страница 23: ...these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic and so on should be disposed of as solid urban waste and simply separated from other waste for recy...

Страница 24: ...Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941 Page 24 Manual FA01237 EN 07 2018 CAME S p A The contents of this manual may change at any time and without notice Tran...

Отзывы: