Obstruction detection with motor idle
0 = Deactivated (
default
) / 1 = Activated
With the barrier closed, open or after a total stop, the operator stays still if the safety devices (photocells and sensitive edges) detect an
obstruction.
F10 Warning
light
0 = lit with boom raised and moving (default) /
1 = fl ashes intermittently each half second when opening
when closing it fl ashes intermittently every second
permanently lit with the boom raised
off with the boom lowered
It warns of the barrier status. The light bulb is connected to 10-5.
F 15
Luminous cord intermittance
0 = Moving boom (default) /
1
= Moving and closed boom
It warns of the status of the barrier with intermittent lights.
F19
Automatic closing time
0 = Deactivated (
default
) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The fi rst automatic-closing wait starts when the opening limit-switch point is reached and can be set to between 1 and 180 seconds. The
automatic closing does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power
outage.
F21 Prefl
ashing
time
0 = Deactivated (
default
) / 1 = 1 s / … / 10 = 10 s
After an opening or closing command, the fl ashing light connected to 10-E6, fl ashes from 1 to 10 seconds before the maneuver starts.
F22 Working
time
5 = 5 s / ...../ 120 = 120 s (
default
)
Gearmotor working time during opening and closing.
The working time can be adjusted between 5 and 120 seconds.
F28
Opening maneuver speed
60 = Minimum speed /… /80 = Speed (
default
) /.... / 100 = Maximum speed.
Setting the boom's opening speed, calculated as a percentage.
⚠
Setting the speed between 90 and 100 automatically increases the percentage of the F 37 opening slow-down starting point.
F 29
Closing maneuver speed
60 = Minimum speed /… /80 = Speed (
default
) /.... / 100 = Maximum speed.
Setting the boom's closing speed, calculated as a percentage.
⚠
Setting the speed between 90 and 100 automatically increases the percentage of the F 38 closing slow-down starting point.
F 30
Opening slow-down speed
10 = Minimum speed /…/ 15 = Speed (
default
) /..../ 30 = Maximum speed
Setting the boom's opening slow-down speed, calculated as a percentage.
F31
Closing slow-down speed
10 = Minimum speed /…/ 15 = Speed (
default
) /..../ 30 = Maximum speed
Setting the boom's closing slow-down speed, calculated as a percentage.
F33 Calibration
speed
10 = 10% of the travel (minimum) / … / 20 = 20% of the travel (
default
) /..../ 30 = 30% of the travel
(maximum)
Setting the boom's travel automatic calibration, calculated as a percentage
F34
Boom travel sensitivity
10 = maximum sensitivity / … / 100 = minimum sensitivity (
default
)
Adjusting obstruction detection sensitivity during boom travel.
F35 Slow-down
sensitivity
10 = maximum sensitivity / … / 100 = minimum sensitivity (
default
)
Adjusting obstruction detection sensitivity during slow-down.
F37
Opening slow-down point
40 = 40% of the travel / … / 50 = 50% of the travel
(
default
)
/… / 70 = 70% of the travel
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down point.
F38
Closing slow-down point
40 = 40% of the travel / … / 50 = 50% of the travel
(
default
)
/… / 60 = 60% of the travel
Percentage adjustment of the boom's total travel, from the beginning of the opening slow-down point.
U 1
Entering a user
1 = Step-step command (open-close) / 2 = Sequential command (open-stop-close-stop) / 3 = Open only command
IUp to a maximum of 25 users can be entered and each can be associated to a function of choice among those available. Entering is done via
transmitter or other control device (see ENTERING USERS AND ASSOCIATED COMMANDS)
U 2
Deleting a user
To delete a user (see DELETING SINGLE USERS paragraph)
U 3
Deleting users
0 = Deactivated / 1 = Deleting all users
Deleting all users.
Содержание G3000
Страница 25: ...INSTALLATION AND OPERATION G3000 G3000I FAST AUTOMATIC BARRIERS FA00028 EN English EN...
Страница 49: ...MANUEL D INSTALLATION G3000 G3000I BARRI RES AUTOMATIQUES RAPIDES FA00028 FR Fran ais FR...
Страница 73: ...G3000 G3000I FA00028 RU RU...
Страница 74: ...2 FA00028 RU FA00028 RU 1 5 2015 Came S p A CAME S p A 2 5 20 CE 1 8 1 5 EN 12453 EN12445 8...
Страница 79: ...7 FA00028 RU FA00028 RU 1 05 2015 Came S p A 600 G3000SX G3000ISX G3000DX G3000IDX...
Страница 85: ...1 8 9 13 13 FA00028 RU FA00028 RU 1 05 2015 Came S p A...
Страница 92: ...20 20 FA00028 RU FA00028 RU 1 5 2015 Came S p A...
Страница 93: ...4 21 21 FA00028 RU FA00028 RU 1 05 2015 Came S p A Er1 Er3 Er4 Er5 Er6 Er7 Er8 C0 1 2 C1 C4 C5 C9...