4.2 Technical information

—#

—#

4.3 Parts description

AUTOMATION UNIT

ACCESSORIES

VIEW FROM THE BAR 

SUPPORT BRACKET

VIEW FROM INSPECTION 

HATCH

GEARMOTOR 

Power supply: 230V A.C. 50/60Hz
Motor power supply: 24V D.C. 50/60Hz
Max. absorption: 1.3A (230V) / 15A (24V) 
Rated power: 300W
Max. torque: 600 Nm
Reduction ratio: 1/202

Opening time: 4÷8 s
Operative intermittence: intensive operation
Protection level: IP54
Weight: 90 kg
Insulation class: I

 1) 

G02000/G04000 - aluminium bar, painted white, Ø 100 mm

 

 2) 

G02040 - Ø40 (yellow) balancing spring

 

3) 

G04060 -Ø50 (green) balancing spring

 4) 

G06080 - Ø55 (red) balancing spring

 

5) 

G02806 - Rack

 6) 

G02802 - Support for DIR photoelectric cells

 

7) 

G02803 - Luminous cord

 

8) 

G02807 - Fixed barrier support

 9) 

G02808

 

- Mobile barrier support

10) 

G02809 - Adhesive reflector strips

11) 

G02801 - Flashing dome lamp

12) 

G02805 - Emergency battery housing support

13) 

ZL38 - Electric board designed to accommodate radio board coupling                                                                                            

14) 

G06803 - Telescopic joint and additional insert to attach the bar

1) Upper dome
2) Bar beam plate

 

3) Bar fitting intermediate plate
4) Cover for aluminium bar
5) Anti-shearing protection cover 
6) Sheet-steel or stainless steel cabinet with 
galvanized and painted finish  
7) Features for housing accessories
8) ABS container for electric 
board with transformer 
9) End-stop assembly
10) Lever arm
11) Transmission rod
12) Inspection hatch
13) Bar position adjustment buffers
14) Gearmotor

Intelligent Security & Fire Ltd.

Содержание G2080I

Страница 1: ...AUTOMATION FOR STREET BARRIERS INSTALLATION MANUAL GARD 8 SERIES G2080 G2080I I n t e l l i g e n t S e c u r i t y F i r e L t d...

Страница 2: ...r accesses of over 3 6m 003 ZL38 Electric board designed to accommodate radio board coupling 002 LB38 Board for the connection of three 12V 6Ah emergency batteries The following accessories are option...

Страница 3: ...low balancing spring 3 G04060 50 green balancing spring 4 G06080 55 red balancing spring 5 G02806 Rack 6 G02802 Support for DIR photoelectric cells 7 G02803 Luminous cord 8 G02807 Fixed barrier suppor...

Страница 4: ...t continuity are allowed as long as they include additional insulation with respect to other internal drive parts Install suitable tubes and ducts for electric cable passage to guarantee protection ag...

Страница 5: ...le 20 30 m 230V 2F power supply FROR CEI 20 22 CEI EN 50267 2 1 3G x 1 5 mm2 3G x 2 5 mm2 3G x 4 mm2 24V motor power supply 2 x 1 mm2 2 x 1 5 mm2 2 x 2 5 mm2 Photoelectric cells TX 2 x 0 5 mm2 2 x 0 5...

Страница 6: ...e and prepare sheath tubes from the branch pit for the connections Remove the nuts and washers from the threaded screws position the cabinet on the base in correspondence with the 4 threaded screws an...

Страница 7: ...opening must be inverted Proceed in the following manner remove the spring securing bracket and the transmission rod from the lever arm loosen the motor support grub screw rotate the lever arm by 90 F...

Страница 8: ...ut in one UNI 5931 M8x20 screw without tightening it to facilitate bar assembly UNI5931 M8x20 UNI5931 M8x12 Insert it in the bar s conduit a procedure that should be carried out on both sides Insert t...

Страница 9: ...age clearance lamp m 2 2 5 3 3 5 4 4 5 5 5 5 6 6 5 7 7 6 By Bare bar we mean a bar complete with the transparent slot cover and end plug 400 mm UNI6954 3 9x19x12 Prior to bar balancing select a suitab...

Страница 10: ...osition the bar vertically and then refasten the gearmotor Hook the tie rod to the anchoring racket Perform the same procedure if there is a second screw Insert the UNI5739 M12X70 screw into the sprin...

Страница 11: ...te make sure the spring functions properly the spring is loose when the bar is in the vertical position at rest the spring is tight when the bar is in the horizontal position tense 5 7 Electric board...

Страница 12: ...total stop 5 8 End stop adjustment Power up the electric board carry out a series of steps to make sure of the bar s correct opening and closing positions and then if necessary proceed to the adjustm...

Страница 13: ...ci S p A ENGLISH After bar opening and closing adjustment tighten the locking nuts under the dampers After making adjustments and settings from the control panel put the container lid in place and sec...

Страница 14: ...atch with the key and The unit opens but does not close 4 7 10 2 Disable steady movement with dipswitch The unit shuts but does not open 7 9 3 Check power supply and fuses No automatic closure 11 12 1...

Страница 15: ...d given to qualified service companies for proper disposal Prior to disposal it is always advisable to check specific regulations in force in the place of disposal PLEASE DISPOSE OF PROPERLY 7 Demolit...

Страница 16: ...06 CAME CANCELLI AUTOMATICI CAME UNITED KINGDOM LTD UNIT 3 ORCHARD BUSINESS PARK TOWN STREET SANDIACRE NOTTINGHAM NG10 5BP U K Tel 0044 115 9210430 Fax 0044 115 9210431 I n t e l l i g e n t S e c u...