background image

FA00008-EN v.7 – 05/2017 

23 

CAME S.p.A. 

 

8. ELECTRONIC CONTROL ADJUSTEMENT 

The electronic control has 4 buttons and 4 alphanumeric displays to set all the necessary adjustments. 

After turning on the electronic control, the display shows the word "MENU". The operation of the four keys are indicated in 
the table. 

Keys 

Description 

 

ENTER 

Select  button,  each  time  you  press  the  button  you  enter  on  the 
selected parameter. 
Save button, pressing for 1 seconds you "SAVE" the selected value. 
MENU = Main parameters menu 
MEM = Memory management menu 
ADV = Advanced parameters menu 
SEL = Function selector menu 
INFO = Information and diagnostics menu 

ESC 

Exit button, exit from all the parameter or exit from the menu. 

↑ 

Scroll button, each press selects a menu item or increases the value 
of the selected item. 

↓ 

Scroll button, each press selects a menu item or reduces the value of 
the selected item. 

8.1 BASIC SETTINGS MENU 

Using the buttons ↑ and ↓ choose MENU, press ENTER to select and adjust the following main parameters: 

Display 

Description 

Factory settings 

DOOR 

DOOR TYPE 

Setting the automation type. Choose between the following values: 
SW2 = SW2 automation PBB2 (LIGHT) 
SW4 = SW4 automation PBBS2 (SPRING) 
SW5 = SW5 automation PBB3 (HEAVY) 

SW2 

OPEN 

OPENING 
DIRECTION 

Setting the opening direction. Choose between the following values: 
← = door hinged on left 
→ = door hinged on right 

← 

ARM 

ARM TYPE 

Setting the type of arm. Choose between the following values: 
PULL = sliding arm 
PUSH = articulated arm 

PULL 

VOP 

OPENING 
SPEED 

Opening speed setting. Choose between the minimum and maximum: 
minimum value = 15 deg/s 
maximum value = 70 deg/s 

50 

VCL 

CLOSING 
SPEED

 

Closing speed setting. Choose between the minimum and maximum: 
minimum value = 100 mm/s 
maximum value = 700 mm/s 

50 

TAC 

CLOSING TIME 

Open door time setting. Choose between the minimum and maximum: 
NO = the door is always open 
minimum value = 1 s 
maximum value = 30 s 

PUSH 

MOTOR 
POWER 

Force setting. Choose between the minimum and maximum: 
minimum value = 1 
maximum value = 10 

10 

LEAF 

DOOR WEIGHT 

Setting the weight of the door. Choose between the following values: 
MIN = light door 
MED = medium door 
MAX = heavy door 

MED 

RAMP 

ACCELERATION 
TIME 

Set the acceleration time. Choose between the minimum and maximum values: 
minimum value = 100 ms (maximum acceleration) 
maximum value = 2000 ms (minimum acceleration) 

400 

BTMD 

BATTERY 
MODE 

Setting operation of battery power device, in absence of electricity. Choose between the following 
values: 
NO = battery not connected 
EMER = emergency open 
CONT = continuation of normal operation of the door, with last cycle of opening 
Note: the number of operations with battery, depends on the efficiency of the battery, the weight of 
the doors and the present friction. 

NO 

 

 

Содержание FLUO-SW

Страница 1: ...ASSEMBLY AND INSTALLATION MANUAL FLUO SW SWING DOOR OPERATOR FA00008 EN EN English...

Страница 2: ...he safety devices safety sensor photocells etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces dev...

Страница 3: ......

Страница 4: ...ay Parameter Settings Buttons and Display Parameter Settings Buttons and Display Connections to control and safety devices Dedicated connecting terminals Connections to control and safety devices Dedi...

Страница 5: ...001MR8106 001MR8107 Unidirectional microwave opening sensor Bidirectional microwave opening sensor 5 001PBBA04 Electronic function selector with transponder key 001PBBA03 001PBBA05 Battery power devi...

Страница 6: ...the automation in a stable and leveled way to the wall using the measurements shown in the figure refer to the axis of the door hinges Fix the sliding arm on the door as shown in the figure Insert the...

Страница 7: ...BA06 45 001PBBA02 62 001PBBA02 001PBBA08 Fix the articulated arm to the automation and fix the other end of the articulated arm to the door Move the door in the closed position and adjust the length o...

Страница 8: ...e sliding arm to pull with doors which open inside view from the automation If the door has the hinge on the right disassemble the gear motor group from the automation and move the spring group from t...

Страница 9: ...eplacing the spacer using the codes listed in the table H PBBS2 automation 30 001PBBA01 001PBBA06 47 001PBBA01 64 001PBBA01 001PBBA08 PRE CHARGING OF THE CLOSING SPRINGS Tighten the screw a and compre...

Страница 10: ...he automation as described in chapter 4 5 Hinge on the left Factory setting Remove the cover and fix the automation in a stable and leveled way to the wall using the measurements shown in the figure r...

Страница 11: ...ulated arm as shown in figure PRE CHARGING OF THE CLOSING SPRINGS Tighten the screw a and compress the springs of about X 5 mm as shown in the figure Move the door manually and verify the correct open...

Страница 12: ...e guide and fix to the automation Note if necessary you can change the measure H between the automation and the door by replacing the spacer using the codes listed in the table H PBB3 automation 28 00...

Страница 13: ...the articulated arm to the automation and fix the other end of the articulated arm to the door Move the door in the closed position and adjust the length of the half arm A so that the angle between th...

Страница 14: ...e to allow recharging the battery power device must always be connected to the electronic control In case of long periods of inactivity of the automatic door disconnect the battery from the electronic...

Страница 15: ...V ELLK LOCK or SAFE AUTO Set the operating time of the electric lock using menu ADV TRLK from 0 5 to 5 0 seconds Set the start of the door opening delay time using menu ADV TALK from 0 5 to 5 0 second...

Страница 16: ...authorized activations Check that upstream of the electrical installation an adequate residual current circuit breaker and an overcurrent cut out are fitted When requested connect the automation to an...

Страница 17: ...connect safety devices with test see terminal 41 and remove the jumper 41 6A 41 Output test 12 V Connect the safety devices with test in accordance with EN 16005 as indicated in the following chapters...

Страница 18: ...h 2 automations when selected the symbol lights and allows the automatic operation of only one leaf Automatic one way operation When selected the symbol lights up and automatic operation of the door i...

Страница 19: ...R8106 001MR8107 OPENING SENSOR Connect the sensor using the supplied cable to the terminals of the electronic control as follows white wire terminal 0 brown wire terminal 1 yellow wire terminal 1 gree...

Страница 20: ...red wire terminal 41 pink wire do not connect purple wire do not connect gray wire do not connect black wire do not connect 8A SENSOR WITH DIP1 OFF Connecting the safety closing sensor 8A set DIP1 OF...

Страница 21: ...plied connect the 2 automations MASTER SLAVE as shown in the figure Using the menu of the electronic control set ADV SYNC MAST on MASTER automation and ADV SYNC SLAV on SLAVE automation Connect the op...

Страница 22: ...terminal NO terminal 3A or terminal 3B For more information check the installation manual of the sensor 7 9 ELECTRICAL CONNECTION OF 001TSP01 TRANSPONDER PROXIMITLY READER Connect the badge reader usi...

Страница 23: ...the opening direction Choose between the following values door hinged on left door hinged on right ARM ARM TYPE Setting the type of arm Choose between the following values PULL sliding arm PUSH artic...

Страница 24: ...ES upload the menu settings from the micro SD memory NO SOUT SETTING OUTPUT You can save the menu settings of automation in use in the micro SD memory Choose between the following values NO no save YE...

Страница 25: ...heavy push MED PUGO PUSH GO Push opening activation Choose between the following values NO off YES active disabled with PWAS YES PWAS POWER ASSIST Manual operation of the door in servo assisted mode...

Страница 26: ...intenance cycles set using the menu INFO SERV WARN Output 0 G1 12Vdc 20mA The output is activated when at least one warning remains active for 5 minutes For remove the alarm signal make a reset or tur...

Страница 27: ...selector accessible with badge and numeric code NO DLAY DELAY CLOSED DOOR Setting delay time function closed door Choose between the minimum and maximum values minimum value 1 s maximum value 5 min 1...

Страница 28: ...at you want to store one at a time to the function selector in front of the NFC symbol the buzzer emits 1 beep of confirmation storage wait for 20 seconds the buzzer emits 2 beeps at the end of the st...

Страница 29: ...n the micro SD memory Choose between the following values NO no save YES save the stored badges and numeric codes in the micro SD memory NO 8 5 INFORMATION AND DIAGNOSTICS MENU Using the buttons and s...

Страница 30: ...No power supply Check the power supply W129 1 No battery Check the battery connection W130 1 Low Battery Replace or recharge the battery W140 3 6A safety test failure Check the safety sensor connecti...

Страница 31: ...follow MENU DOOR SW4 confirm by pressing ENTER for 1 second Note if the door is PBB3 HEAVY model set as follow MENU DOOR SW5 confirm by pressing ENTER for 1 second 9 5 Perform the menu settings as de...

Страница 32: ...set Function selector incorrectly set Check and correct the settings of the function selector Control devices or safety always activated Disconnect devices from the terminal and verify the operation...

Страница 33: ...rm on the door In the case of SW4 automation check the correct force of the closing spring If present verify proper engagement of the electric lock Every 6 months or every 500 000 cycles Connect the p...

Страница 34: ...on di Casier Treviso Treviso Italy 33079 Sesto al Reghena Sesto al Reghena Pordenone Pordenone Italy 39 0422 4940 39 0422 4941 39 0434 698111 39 0434 698434 s a f e t y c o m f o r t English Manual co...

Отзывы: