25
6.2 - Function Selections
1 ON Automatic closing enabled.
1 OFF Automatic closing disabled.
2 ON ‘Open-stop-close-stop’ function with button (2-7)
and radio control (AF board inserted) enabled.
2 OFF ‘Open-close’ function with button (2-7) and radio
control (AF board inserted) enabled.
6.3 - Technical Description - ZF1 Control Panel
Description
The ZF1 control board is suitable for controlling 230V single-phase automated gates with power up to
320W, for FAST series ratiomotors (residential swing gates).
The board must be powered at 230V (a.c.) on the L1 and L2 terminals, and the inlet is protected with
a 5A fuse, while the low voltage (24V) accessories are protected with a 3.15A fuse.
The accessory's total capacity (24V) should not exceed 20W.
Safety
Photocells can be connected to abtain:
- Re-opening during closure (2-C1), if the photocells identify an obstacle while the gate is closing, they
will reverse the direction of movement until the gate is completely open;
- Total stop (1-2), shutdown of gate movement without automatic closing, a pushbutton radio remote
control must be actuated to resume movement.
Optional accessories
- 12V Electric lock (ES-ES);
- Open gate pilot lamp (3W max.). Lamp that signals the gate is open, turns off when the time fixed
for the gate’s closing has elapsed (10-5).
Other functions
- Automatic closing. The automatic closing timer is automatically activated at the end of the opening
cycle. The preset, adjustable automatic closing time is automatically interrupted by the activation of
any safety system, and is deactivated after a STOP command or in case of power failure;
- "Operator present". Gate operates only when the pushbutton is held down (the radio remote control
system is deactivated). It is activated when the T.L. trimmer is set to the minimum.
Adjustments
- Automatic closure time;
- Delay in closing of the M2 motor;
- Operating time.