Total stop [1-2]
0 = Disabled (default) / 1 = Enabled
NC input - The gate is stopped and any automatic closing is disabled. To resume movement, use the control device. The safety device must be inserted on
[1-2].
F2 Input
[2-CX]
0 = Disabled (default) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7 / 8 = C8
NC input - Possibility of associating: C1 = reopening during closing for photocells, C2 = reclosing during opening for photocells, C3 = partial stop, C4 =
waiting for obstacle, C7 = reopening during closing for sensitive edges, C8 = reclosing during opening for sensitive edges.
F3 Input
[2-CY]
0 = Disabled (default) / 1 = C1 / 2 = C2 / 3 = C3 / 4 = C4 / 7 = C7 / 8 = C8
NC input - Possibility of associating: C1 = reopening during closing for photocells, C2 = reclosing during opening for photocells, C3 = partial stop, C4 =
waiting for obstacle, C7 = reopening during closing for sensitive edges, C8 = reclosing during opening for sensitive edges.
F5 Safety
test
0 = Disabled (default) / 1 = CX / 2 = CY / 3 = CX+CY
After each opening or closing command, the panel checks that the photocells work correctly.
F6 Hold-to-run
0 = Disabled (default) / 1 = Enabled
The gate opens and closes when a button is pressed. Button to open the contact [2-3] and button to close the contact [2-4]. All other control devices, also
radio, are disabled.
F7 Command
[2-7]
0 = step-by-step (default) / 1 = sequential
Step-by-step = open-close, sequential = open-stop-close-stop.
F8 Command
[2-3P]
0 = pedestrian opening (default) / 1 = partial opening
Pedestrian opening (complete opening of the second leaf) or partial opening (partial opening of the second leaf: the degree of opening depends on the per-
centage of run adjustment set with F36).
F9
Obstacle detection with the motor at a standstill
0 = Disabled (default) / 1 = Enabled
With the gate closed, open or after a total stop, the gearmotor remains at a standstill if the safety devices (photocells or sensitive edges) detect an obstacle.
F10 Indicator
light
0 = on when the gate is open and moving (default) /
1 = fl ashes intermittently every half second during opening
fl ashes intermittently every second during closing
on steady when the gate is open
off when the gate is closed
Indicates the status of the gate. The bulb is inserted on the 10-5 contact.
F11 Encoder
disabling
0 = encoder enabled (default) / 1 = encoder disabled
Excludes management of slowdowns, obstacle detection and sensitivity.
F14
Sensor type selection
0 = command with transponder sensor or magnetic card reader
1 = command with keypad (default)
Setting the type of sensor for controlling the operator.
F16 Water
hammer
0 = Disabled (default) / 1 = Enabled
Before each opening and closing manoeuvre, the leaves push to the end of their run to facilitate the release of the electric lock.
F18 Additional
lamp
0 = Flashing light (default) / 1 = Cycle
Exit on the contact [10-E].
The fl ashing light works during opening and closing.
The cycle lamp remains on from the start of opening to complete closing, including the wait time before automatic closing.
F19
Automatic closing time
0 = Disabled (default) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The wait before automatic closing starts from reaching the end run point for a time that can be set between 1 and 180 seconds. Automatic closing is not
activated in the event that the safety devices intervene after detecting an obstacle, after a total stop or in the event of a power failure.
F20
Automatic closing time after partial opening
5 = 5 s (default) / 1 = 1 s / 2 = 2 s / … / 180 = 180 s
The wait before automatic closing starts from a partial opening or pedestrian command for a time that can be set between 1 and 180 seconds. Automatic
closing is not activated in the event that the safety devices intervene after detecting an obstacle, after a total stop or in the event of a power failure.
F19 does not have to be disabled.
F21 Pre-fl ashing time
0 = Disabled (default) / 1 = 1 s / 2 = 2 s / … / 5 = 5 s
When an opening or closing command is sent, the fl ashing light on [10-E] fl ashes before starting the manoeuvre. The fl ashing time can be set between 1 s
and 5 s.
F22 Working
time
5 = 5 s / 6 = 6 s / … / 120 = 120 s (default)
Gearmotor operating time, during opening and closing. This can be set between 5 and 120 seconds.
Function menu