IMPORTANT! Start programming while respecting the order of the features shown on the list
below.
⚠
Only program functions when the operator is stopped.
When programming is finished, set all Dip-switches to OFF.
You can save up to 25 users.
IMPORTANT! Start programming by first running the Opening direction, TOTAL
STOP and Self-learning functions, respectively.
DIP-SWITCH Description of functions
Opening direction
By default, the operator is programmed for being installed on the left.
For installing on the right:
select the DIP switches as shown and press the P1 key on the control board. The LED stays on and the
buzzer sounds off for one second.
Press P1 to return to the default parameters. The LED blinks and the buzzer sounds off twice.
P1 key
FUNCTIONS PROGRAMMING
Red LED (PRG)
DIP-SWITCH
SAFETY DEVICES
Connecting the safety devices (i.e. the safety test)
At each opening and closing command, the control board checks the efficacy of the safety devices (such as,
photocells).
Any anomalies will inhibit all commands.
Enable this function when programming.
Photocells
Configure the CX contact (NC), input for safety devices such as photocells.
When programming the functions the CX input may be set up as:
- C1 reopening during closing. When the gate is closing, opening the
contact triggers the inversion of movement until the gate is fully open again;
- C4 obstruction wait. Stopping of the gate, if it is moving, which resumes
movement once the obstruction is removed.
If unused, the CX contact should be deactivated during programming.