Closing slow-down
point
Percentage adjustment of the total door travel, from the closing slow-down starting point.
This function only appears when functions F11 and F30 are activated.
5
= 5% of the gate travel /... /
15
= 15% of gate travel (
default
) /... /
30
= 30% of gate travel
F48
Maneuver thrust
activation
Greater pushing torque that activates during the operator's beginning opening and closing phases.
OFF
(
default
) /
ON
F49
Managing the serial
connection
To enable the paired operating mode or the CRP (Came Remote Protocol).
OFF
(
default
) /
1
= Paired /
3
= CRP
F50
Saving data
Saving users and saved settings in memory roll.
This function only appears if a memory roll has been fi tted into the control board.
OFF
(
default
) /
ON
F51
Uploading date
Uploading data saved in memory roll.
This function only appears if a memory roll has been fi tted into the control board.
OFF
(
default
) /
ON
F52
Transferring
parameters in paired
mode
Uploading settings from Master to Slave.
This appears only if function F49 is set to Paired.
OFF
(
default
) /
ON
F54
Opening
direction
For setting the gate opening direction.
0
= Opening left (
default
) /
1
= Opening right
F56
Peripheral number
To set the peripheral number from 1 to 255 for each control board when a system is fi tted with several
operators and features the CRP (Came Remote Protocol) connection system.
1 ----> 255
F63
COM speed
For setting the communication speed used in the CRP (Came Remote Protocol) connection system.
0
= 1200 Baud /
1
= 2400 Baud /
2
= 4800 Baud /
3
= 9600 Baud /
4
= 14400 Baud /
5
= 19200 Baud
/
6
= 38400 Baud (
default
) /
7
= 57600 Baud /
8
= 115200 Baud
F65
Wireless input
RIO-EDGE [T1]
RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and
exclude any automatic closing; to resume movement, use the control device, P7 = reopening during closing,
P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
OFF (default) / P0
= P0
/ P7
= P7
/ P8
= P8
F66
Wireless input
RIO-EDGE [T2]
RIO-EDGE wireless safety device associated to a function of choice among those available: P0= stop gate and
exclude any automatic closing; to resume movement, use the control device, P7 = reopening during closing,
P8 = reclosing during opening.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
OFF (default) / P0
= P0
/ P7
= P7
/ P8
= P8
F67
Wireless input
RIO-CELL [T1]
RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 =
reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
The P3 function appears only if the F19 function is activated.
OFF (default) / P1
= P1
/ P2
= P2
/ P3
= P3 /
P4
= P4
F68
Wireless input
RIO-CELL [T2]
RIO-CELL is associated to any function chosen among those available: P1 = reopening during closing; P2 =
reclosing during opening; P3 = partial stop; P4 = obstruction wait.
For programming, see the instructions that come with the accessory.
This function only appears if the RIOCN8WS card is plugged into the control board.
The P3 function appears only if the F19 function is activated.
OFF (default) / P1
= P1
/ P2
= P2
/ P3
= P3 /
P4
= P4
F71
Partial opening time
After an opening command from the button connected to 2-3P, the gate opens for an adjustable time of
between fi ve seconds and 40 seconds.
This function only appears if function F11 is deactivated.
5
= 5 Seconds (
default
) /... /
40
= 40 Seconds