F6 Maintained
action
OFF
(
default
) /
ON
The gate opens and closes by keeping the button pressed. Opening button on contact 2-3 and closing button on contact 2-4. All other control
devices, even radio-based ones, are excluded.
F7 Command
(2-7)
0
= Step-step (
default
) /
1
= Sequential
From the control device connected to 2-7 it performs the step-step (open-close-invert) or sequential (open-stop-close-stop) command.
F9 Obstruction detection with motor
idle
OFF
(
default
) /
ON
With the gate closed, opened or totally stopped, the gearmotor stays idle if the safety devices, that is, photocells or sensitive safety-edges detect
an obstruction.
F10 Gate-open signal output
0
=
On when the barrier is open and moving
(
default
)
/
1
=
during openings it fl ashes intermittently each half second
, and during closings it fl ashes intermittently each
second. It stays on steadily
when the barrier is open, off or when it s closed.
It signals the gate status. The signal device is connected to contact 10-5.
F14 Sensor type selection
0 = control with transponder sensor or magnetic card reader.
1
= command with keypad selector (
default
).
Setting the type of accessory for controlling the operator.
F18 Additional light
OFF
(
default
) /
1
= Cycle /
2
= Courtesy
Extra light connection input on EX-W.
Outdoor light for additional visibility in the drive way.
Cycle: it stays lit from the moment the gate starts opening until it completely closes, including the automatic closing waiting time.
Courtesy: it stays on for an adjustable time of between 60 and 180 seconds. For adjusting the time, see function [
F25
].
F19 Automatic closing time
OFF
(
default
) /
1
= 1 second /… /
180
= 180 seconds
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds. The automatic
closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power outage.
F20 Automatic closing time after a
partial opening
OFF
/
1
= 1 second /…/
10
= 10 seconds (
default
) /…/
180
= 180 seconds
The wait before the automatic closing starts after a partial opening command for an adjustable time of between 1 s and 180 s.
The automatic closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power
outage.
F21 Prefl ashing time
OFF
(
default
) /
1
= 1 second /… /
10
= 10 seconds
Adjusting the pre-fl ashing time for the fl ashing light connected to E1-W, before each maneuver. The fl ashing time is adjustable from one to ten
seconds.
F25 Courtesy light time
60
= 60 seconds (default)
/
180 =
180
seconds
Additional light that stays on for the required time during the when the gate is opening or closing.
EX-W contact output. It is adjustable between 60 seconds and 180 seconds.
F49 Managing serial connection
OFF
(
default
) /
1
= Paired / 3 = CRP
To enable the paired operating mode or the CRP (Came Remote Protocol).
F50 Save data
OFF
(
default
) /
ON
Saving users and saved settings in memory roll.
This function only appears if a memory roll has been fi tted into the control board.
F51 Read data
OFF
(
default
) /
ON
Uploading data saved in memory roll.
This function only appears if a memory roll has been fi tted into the control board.
F52 Passing parameter in paired
mode
OFF
(
default
) /
ON
Uploading settings from Master to Slave.
It appears only if function [
F49
] is set to Paired.
F54 Opening direction
OFF
= Opening left (
default
) /
ON
= Opening right
For setting the gate opening direction.
F56 Peripheral number
1 ----> 255
To set the peripheral's number from 1 to 255 for each control board when you have a system with several operators.