background image

SAFETY INSTRUCTIONS

When correctly installed in compliance to installation instructions and adhering to all 
current electrical, mechanical and manufacturer regulations, your automation system 
will provide a high degree of safety and problem free operation.

 

Please take note of the following warnings that must be followed in order to  

 

prevent accidents during your gate operation:

• 

Do not allow children to play near the gate.

• 

Keep all remote control operating devices out of the reach of children.

• 

Do not pass through the gate whilst in operation. Wait until they are fully open before passing through.

• 

Do not stop unnecessarily when passing through the gate.

• 

Keep feet away from the bottom of the gate during operation.

• 

Do not operate the gate by remote control unless they are in view.

• 

Do not attempt to block or interfere with the gate movement during operation.

• 

Under no circumstances should you attempt to modify the gate automation system.

• 

Ensure that your gate is serviced at 3 to 12 month intervals (dependent on number of openings) by your installation/
maintenance company.

• 

Report any signs of malfunction to your installation/maintenance company immediately.

• 

In the case of malfunction, isolate the power supply, release any additional locking mechanism, manually open the 
gate (see manual release instruction booklet) and call your installation/maintenance company.

• 

If you are in any doubt regarding the operation of your gate, call your installation/maintenance company.

Содержание ATS-P5

Страница 1: ... Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a pair of swing gates weighing up to 400kg per leaf max width 5m TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL ...

Страница 2: ...d code Transmitter ATS50AGS Motor x2 ATS P5 KIT CONTENTS x2 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Panel Quick Start Guide 8 Control Panel Programming Transmitters 9 Connect Setup 10 Control Panel Safety 11 Optional Accessories ...

Страница 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate movement during operation Under no circumstances should you attempt to modify the gate automation system Ensure that your gate is serviced at 3 to 12 month intervals dependent on number of openings by...

Страница 4: ... glands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection rating Only a competent service provider should open the enclosure and adjust the settings The photocells are used in pairs one transmitter and one receiver They should be installed between 500 600mm fro...

Страница 5: ... mm F mm C max mm 90 200 200 1030 1430 150 90 200 270 1030 1510 200 120 200 140 1030 1460 70 Preliminary checks Side hung gate GEOMETRY 5m Tick 1 Check that the gate structure is sturdy enough the hinges work efficiently and that there is no friction between the fixed and moving parts 2 Make sure that measurement C does not exceed the value shown in the reference table 3 Make sure that you have fi...

Страница 6: ...carefully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic Maintenance Hints Tips Open manual release cover spray locking mechanism with suitable penetrating lubricant Lubricate gate hinges Manually release the gates at least once per month ALWAYS isolate ...

Страница 7: ... TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m AF43S Plug in TOP A433N Antenna Cable length RG58 Max 5m ATS50AGS Gate motors Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm Mains Supply 230 V AC Cable length 1m 20m 3 Core 1 5mm 20m 30m 3 Core 2 5mm The Earth cable should be connected to the motor chassis ...

Страница 8: ...ir closed positions For each gate motor complete the following steps Send a closing command pulse using a link wire between terminal 2 4 While the motor is running turn the rod marked C anticlockwise until the motor stops running Set both gates to their open positions For each motor complete the following steps Send an opening command pulse using a link wire between terminal 2 3 While the motor is...

Страница 9: ... held down press and release a button on a transmitter The PROG LED goes solid to signal the successful saving of the code 3 Release the CH1 key A maximum of 25 individual buttons can be saved remove all transmitters 1 Press and hold the CH1 and CH2 buttons simultaneously until the PROG LED stays lit All previously saved transmitter buttons will be removed from the memory of the control board Ensu...

Страница 10: ...ety circuit is triggered the automation will stop and reverse its motion until it reaches its fully closed position again Once the automation has reached the fully closed position it will require another activation from a command device to restart CX PARTIAL STOP When the automation is in its opening cycle and the safety circuit is triggered the automation will stop If the auto closing option is e...

Страница 11: ...ur 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0290 SELT2BDG Flush mounted 12 button Bus keypad with blue backlighting RAL7024 Grey colour 806SL 0370 S0002P External two channel 12 24 V AC DC IP54 control card for key...

Страница 12: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm Business Park Castle Donington DE74 2US Tel 0115 921 0430 CAME BPT South Liberta House Maxted Road Maylands Ind Est Hemel Hempstead Herts HP2 7DX Tel 01442 230 800 CAME BPT Ireland Unit 9 The Westwa...

Отзывы: