background image

ZA3P: 

transmitters 

Should the transmitter not operate as suggested above,

call CAME helpline 

0115 921 0430

 for technical support.

add

 a transmitter button

1. 

Press and hold the 

CH1

 button, the 

PROG. LED

 starts fl ashing rapidly.

 

2. 

While keeping the 

CH1

 button held down press and release a button on a transmitter

 

 The 

PROG. LED

 goes solid to signal the successful saving of the code.

3. 

Release the 

CH1

 key.

 

A maximum of 25 individual buttons can be saved.

remove

 all transmitters

1. 

Press and hold the 

CH1

 and 

CH2

 buttons simultaneously until the 

PROG. LED 

stays lit

 

 

All previously saved transmitter buttons will be removed from the memory of the control board.

L N

U V W X Y E E3

10 11 S 1 2 3 3P 4 5 7

2 C1 CX B1 B2

TS 10

L1T

CT

0 12 24

L2T

2

FC1 FA2 FC2

FA1

L2T

L1T

1

2

3

4

0 12 24

 

L N

U V W X Y E E3

10 11 S 1 2 3 3P 4 5 7

2 C1 CX B1 B2

TS 10

L1T

CT

0 12 24

L2T

2

FC1 FA2 FC2

FA1

L2T

L1T

1

2

3

4

0 12 24

 

Ensure the AF card is fi tted (refer to the wiring diagram).

Содержание Ati-S3

Страница 1: ...ICK SETUP GUIDE Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a single swing gate up to 3m wide TO BE READ IN CONJUNCTION WITH TH...

Страница 2: ...00A Motor x2 ATI S3 KIT CONTENTS topd4Fks Fixed code Transmitter 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Kit Wiring Diagram 7 Control Panel...

Страница 3: ...sing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate m...

Страница 4: ...lands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection ratin...

Страница 5: ...ction between the fixed and moving parts 2 Make sure that measurement C does not exceed the value shown in the reference table 3 Make sure that you have fitted opening and closing mechanical gate stop...

Страница 6: ...the power supply as instructed by your installer even in a power cut Release any additional locking device fitted to the gate eg electric lock etc 1 Raise the door covering the lock A 2 Insert the key...

Страница 7: ...T 0 12 24 L2T 2 FC1 FA2 FC2 FA1 L2T L1T 1 2 3 4 0 12 24 ZA3P Control Panel 10 2 TX C NC TX 2 RX TX DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m AF43S Plug in TOP A433N...

Страница 8: ...total stop Permanent link wire between terminal 1 2 3 If no safety device has been connected to the C1 terminal then disable the safety input C1 Permanent link wire between terminal 2 C1 4 Disable sa...

Страница 9: ...The PROG LED goes solid to signal the successful saving of the code 3 Release the CH1 key A maximum of 25 individual buttons can be saved remove all transmitters 1 Press and hold the CH1 and CH2 butto...

Страница 10: ...ll stop and reverse its motion until it reaches its fully closed position again Once the automation has reached the fully closed position it will require another activation from a command device to re...

Страница 11: ...r 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour HARDWIRED KEYPAD SELECTORS 806SL 0280 SELT1BDG Surface mounted 12 button Bus keypad with blue backlighti...

Страница 12: ...HIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Farm...

Отзывы: