A
B
C
Page
19
- Manual
FB00805-EN
- ver
. 1
- 07/2017 - © C
AME S.p.A. - The cont
ents of this manual ar
e subject t
o change at any time without prior notice.
Setting the unit of measurement
for the temperature
Choose the unit of measurement for the
temperature using the
arrows
A
.
Press the button to move on to the next
parameter to be configured.
Use of terminals
(only on battery-powered model)
Choose the function associated with the termi-
nals
using the
arrows
B
from:
= compatible remote probe
= telephone contact
= window contact
Choice of main probe
(only on battery-powered model)
If you have chosen to connect to the terminals
an external probe (
), press-
ing the button will make the screen in
figure
C
appear.
Using the
arrows you can choose
the function that the external probe must
carry out:
= Secondary probe
= Main probe
Note. If the external probe is set as the main probe, the temperature it detects is shown on the display and
used as a reference for the operation of the heating/cooling system. The temperature detected by the device's
internal probe cannot be seen on the display.