D
A
AB
Page
15
- Manual code
FB00795-EN
- Ed.
1 - 07/2017 - © C
ame S.p.A. - The cont
ents of this manual ar
e t
o be consider
ed as subject t
o change at any time and without the need for any advance warning.
Use buttons 0÷23 to move
the flashing indicator to hour 0 on
the daily programme graphic
B
.
Pull out the unit body.
Use button 1÷7 to move the day
indicator to position 1 (Monday)
A
.
The segment under the selected
day flashes.
The full daily programming chart reappears on the display to confirm that programming
of the temperature ranges has been completed.
10 seconds after the last action the unit exits the procedure and accepts as valid the
data entered up to that moment.
Put the unit body back in.
Note. The value that can be assigned to each temperature range is limited by the values
of the range immediately above and below.
If, for example, range T3 is set at 20°C and range T1 is set at 16°C, the value of range T2
can vary between 16.1°C and 19.9°C; if T2 is set at 21°C, T3 is automatically increased
to 21.1°C.
Customising the temperatures for the daily programme
Press button T to confirm the
temperature value shown on the
display and move on to the next
temperature level
D
.
Do this to set all the temperature
ranges as you want them.