CM-333 Battery Operated with Relay Output Active Infra-red “Hands-Free” Switches Installation Instructions

5502 Timberlea Blvd., 

Mississauga, ON Canada 

L4W 2T7

www.camdencontrols.com 

Toll Free: 1.877.226.3369

Section 4: System Inspection 

Instructions

 

After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10  

  or A156.19 guidelines). This will advise the person  

  entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how to  

  test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of its  

  components become damaged.
4. Strongly recommend to the owner that the complete  

  entry be inspected twice a year as part of the service  

 agreement.

Section 5: Technical Data

No. of IR Sensors

(1)

Batteries (Supplied)    

(2) ‘AA’ Alkaline (Supplied)

Estimated Battery Life

2 Years (Based on 100  

Operations/Day)

Standard Operating 

Range 

1”- 12” (25.4mm - 304mm) 

Factory Set to 6” (152 mm)

Operating Mode

Momentary 

Momentary with Alarm

Inputs

‘Request to Exit’ External  

(Door Contact) Input

Wireless Output

TX-99 Plug-in 915Mhz. Spread Spectrum 

Wireless Transmitter

Relay Output

(1) Form ‘C‘ (SPDT)

Relay Contact Rating

2 Amps @ 30 VDC

Output Type

Fail-secure

File: CM-333 hands-free switches 

manual_R2.indd

Revised: 07/03/2018

 

Part No: 40-82B195

Diagram 5  

Jamb Cutout Dimensions

1’

0’

2’

3’

1”

(25.4mm)

12”

(304mm)

Diagram 6 

Adjustable Range Settings

73mm

7/8" 

2

38 mm

1/2" 

1

3

79mm

1/4" 

Drill & Tap

6-32 (2 holes)

Questions? Call us toll-free at 1-877-226-3369

Page  4 of 4