CM-324 Active Infrared “Hands-Free” Switch Installation Instructions

CX-DA400 Door Prop Alarm Installation Instructions

STEP BY STEP INSTRUCTIONS  

FOR EASY CONFIGURATION

THE DEFAULT SETUP IS FOR ACCESS CONTROLLED, 
AND EMERGENCY EXIT APPLICATIONS.

•  This unit may be connected to power and a closed-loop  

Door Input and be ready to work immediately for the  

Default application.

•  A Voltage Sense input used with a Mag-Lock, and/or a N/C Dry 

Contact Shunt input will require additional jumper configuration 

(J2 and/or J3 respectively) and is covered in Step 3 Pg. 4.

•  The unit is easily configured for a 

stand-alone Door Prop 

application

 by removing the Intrusion Detection jumper.  

(LED will always be Green when Intrusion Detection is disabled.)

TIMER SETTING DEFAULTS: 

(Step 4 Pg.4)

•  Silent Time 5 seconds;
•  Alarm Delay Time 5 seconds
•  Auto Reset Time 5 seconds
•  Shunt Delay 20 seconds

See text for Feature Description and Setup info.

TERMS USED IN THIS INSTRUCTION

N/C DOOR CONTACT

 - is a “closed-loop” circuit which goes open 

when the door is opened.

SHUNT INPUT

 - is a dry contact Valid User Input provided by an 

Access Control System or a PIR / REX device.

DMA

 - Door Management Alarm (i.e.: CX-DA400)

Normally Energized

 - in reference to a Mag-Lock or other locking 

device where power is removed to unlock.

Normally De-energized

 - in reference to a Door Strike or other 

locking device where power is applied to unlock.

DOOR SUPERVISION, AND TAMPER 

1

•  Connect N/C 

Door Contact

 to TS1 7&8.

•  If resistors are installed for 

Door Supervision:

  

A) place Jumper 1 ON and put resistors at door switch as shown in 

Figure 1.   

B) If unused, leave Jumper OFF and use a closed-loop Door Switch 

circuit.

 

•  Tamper Alarm 

(cannot be reset or bypassed)

A) To Enable feature cut cable tie on Tamper Switch located on 

standoff (Component Location on reverse. (CX-DA401 only) 

Page 3 of 6

INTRUSION DETECTION

2

A) Jumper 4 is 

ON

 for Access Control and Emergency Exit Only 

applications. 

B) Jumper 4 is OFF for Door Prop/Held applications without Access 

Control.

NOTE: If OFF, LED is Green  

except during a Door Prop Alarm.  

If OFF, Go to Step 4-Timer Settings. (Skip Step 3)

ACCESS CONTROL

3

•  VOLTAGE SENSE

 monitors Lock Power as “Valid User” input on  

TS1 (3&4)  

A) If unused, Jumper 2 must be 

OFF.

  

B) If used, select: Normally Energized (Jumper 2 ON); or, Normally 

De-Energized (Jumper 2 

OFF

)

VOLTAGE SENSE 

EXPLAINED

 - 

This 

input samples the 

voltage to a Mag 

Lock (J2 ON) or a 

Door Strike* (J2 

OFF) and accepts a 

change in voltage 

as a valid user 

input. *Normally 

de-energized.

•  SHUNT INPUT

 detects a Dry Contact input for each valid access. 

TS1 (1&2)  

A) If unused, Jumper 3 must be 

ON

B) If used, Select: 

Jumper 3 

ON

 for N/O input; or Jumper 3 OFF for N/C input

CX-DA400

Figure 1