Section 3D________________ 
Set-up Instructions 

2-Door Restroom (Mode 4) 

This application is a shared-use (normally unlocked) 
restroom between two suites (and therefore utilizing 
two doors), in facilities such as nursing homes & 
hospitals, etc.  The relay provides control of both 
locks, operators, and all switches, to provide the 
utmost in flexibility, safety for the occupants, yet still 
be easy to install and program. 

Either door is opened automatically by pressing the 
respective exterior wall switch.  Once the door has 
closed, pressing either “Push to Lock” button inside 
then locks both doors – the strike is energized, and  
exterior switches are removed from the circuit.  To 
exit the restroom, simply push either interior wall 
switch.  The respective door unlocks, opens and 
resets the system.  Should either door be opened 
manually, the magnetic contact switch will reset the 
system. 

Unique to the EMF-2 is the emergency input, which 
allows a panic button to unlock, open (one or both) 
door(s), (optional), and send an emergency signal for 
assistance.  The output can be maintained or pulsed.  
As an added safety feature, the EMF-2 can be set to 
automatically reset (and unlock) after 15 minutes 
time. 

It is strongly encouraged to utilize the dry contact 
output (Relay #5) or the 

LED

 output to indicate 

Occupied

” on the exterior of both doors to let others 

know the restroom is in use. 

Step 1

  

Select 

MODE 4

 via the first 3 positions of the 

dipswitch as shown below: 

Off On

1

2

3

 

See diagram 1 for location of dipswitch, connectors, 
& potentiometers. 

 

IMPORTANT:

 Any changes Mode selector or 

Out2

settings must be made with power 

off!

 

 

Step 2 
Dip switch Options 

Leave switch #6 

OFF

 to enable the panic button to 

unlock the door only, but

 not

 open it.  Put dipswitch 

#6 

ON

 when you want the panic button to unlock the 

door 

and also open it

.  Furthermore, if dipswitch #6 is 

set to 

ON

, and dipswitch # 8 is set to 

OFF

, then only 

the last door used will open. Setting dipswitch #8 

ON

will open both doors simultaneously. 

Push dipswitch #7

 ON

, to enable the 15 minute Time-

out (reset) feature. Leave in 

OFF

 position if you 

do 

not

 want an automatic reset. 

Use of Relay 5 is optional, and set according to 
dipswitches #4 & 5.  (See diagram 1 for location).  A 
common use in this mode would be to have Relay 5  
follow the lock relay and light an occupied sign.  It 
could also be utilized for the second door lock, rather 
than connecting both door locks to Relay #1 output.   
By default, Relay #5 follows Relay #1. 

Step 3 
Connections

 

Refer to Diagram 5 (page 10) for the following 
connections. 

Wire all input connections to the (removable) 

Input 

terminal strip

 (numbered 1 - 14).  Firmly re-insert 

connector if removed. 

Next, make your connections to the 

relay output strip

 

(numbered 1 – 15).  Both door locks may be 
connected to relay #1 or, wire one lock to Relay #1 
and the other to Relay #5.  Re-insert connector. 

The 7-pin 

Digital I/O strip 

provides either 12V DC or 

5V DC on Terminals 6 & 7 for lighting “

Occupied

” 

LED’s.  This output is present whenever the door is 
locked.  Select output voltage using jumper as shown 
below: 

LED Output

12V

5V

 

Finally, connect 12 or 24 Volt AC or DC supply to 
terminals 1 & 2 of the 2-pin Power Connector. 
(The terminals 

are not

 polarity sensitive). 

Step 4  Adjustments 

In this application, you will use pots 2 – 5.  Pot #1 has 
no effect. 

Timer 2  

Operator Delay-on-activate 

Timer 3  

Operator Delay-on-release 

Timer 4  

Panic Relay (#4) ON time 

Timer 5  

Panic Relay (#4) OFF time 

 

 

Note: If pot 5 is turned to zero, 

                          relay will be on steady 

Apply power to door operators, EMF-2, and all 
connected equipment (ie – strikes, lights, etc). 

 

Observe the red Power LED on the unit, which 
should light.  If not, re-confirm proper voltage and/or 
terminal strip connection. 

Page 11 of 19

Содержание EMF-2

Страница 1: ...wiring from all door actuators to this unit as well as the lock operator and door contact outputs as appropriate The EMF 2 is also available in an attractive lockable metal cabinet version EMF 2m or E...

Страница 2: ...1 Power Input P1 2 Power Input 12 24 Volts AC DC Non polarized 1 Ground 2 Blue or Brown 3 N C or Yellow 4 CR Power 5V 5 Orange output 1 6 Output 2 P2 7 Ground 2 Card Reader Input aka Digital Connector...

Страница 3: ...iagram 1 for location Dipswitches 7 8 have no effect in this mode Step 3 Connections Refer to Diagram 2 next page for the following connections Wire all input connections to the removable Input termin...

Страница 4: ...r Operator RELAY 5 CHART To have Relay 5 shadow another relay set dipswitch as shown at right 2 4 3 1 ON ON ON ON OFF OFF OFF OFF Dip 4 Dip 5 N C Page 4 Simple Micro switch type Card reader 1 Timer Se...

Страница 5: ...tch will reset the system Unique to the EMF 2 is the emergency input which allows a panic button to unlock open the door optional and send an emergency signal for assistance The output can be maintain...

Страница 6: ...Fail Secure lock is used wire to Terminals 1 2 PUSH TO LOCK Optional Power for Strike Optional OCCUPIED Door Operator RELAY 5 CHART To have Relay 5 shadow another relay set dipswitch as shown at righ...

Страница 7: ...ncy Time out Feature An added safety feature in the EMF 2 is the ability to automatically reset to standby mode after a fixed lock time of 15 minutes The door will unlock so that personnel may enter t...

Страница 8: ...rminals 1 2 PUSH TO LOCK Optional Power for Strike Optional OCCUPIED Door Operator RELAY 5 CHART To have Relay 5 shadow another relay set dipswitch as shown at right 2 4 3 1 ON ON ON ON OFF OFF OFF OF...

Страница 9: ...ights etc Observe the red Power LED on the unit which should light If not re confirm proper voltage and or terminal strip connection Enter keypad key switch or other credential to activate EMF 2 Depen...

Страница 10: ...ls 1 2 PUSH TO LOCK Door 1 Lock Optional RELAY 5 CHART To have Relay 5 shadow another relay set dipswitch as shown at right 2 4 3 1 ON ON ON ON OFF OFF OFF OFF Dip 4 Dip 5 N C Assistance Required Page...

Страница 11: ...ou want the panic button to unlock the door and also open it Furthermore if dipswitch 6 is set to ON and dipswitch 8 is set to OFF then only the last door used will open Setting dipswitch 8 ON will op...

Страница 12: ...Page 12 TO OPEN PUSH TO OPEN PUSH TO OPEN PUSH Door Contact A Door Contact B N C N C Door A Operator Door B Operator Door C Operator 1 Timer Settings Relay On Indicators EMF 2 1 5 2 3 4 6 7 8 9 10 11...

Страница 13: ...MF 2 is the ability to automatically reset to standby mode after a fixed lock time of 15 minutes The door will unlock so that personnel may enter the restroom This feature is engaged by turning dipswi...

Страница 14: ...Indicators EMF 2 1 5 2 3 4 6 7 8 9 10 11 12 13 14 15 1 5 2 3 4 6 7 1 5 2 3 4 6 7 8 9 10 11 12 13 14 Off On 1 2 5 7 4 6 3 8 Mode Rel 5 Opt 2 3 4 5 LED Output 12V 5V Power ON NC NC NC NC NC NO NO NO NO...

Страница 15: ...irst has closed If there is a succeeding request on the first door or the door that is already opened it will keep that door opened If automatic sequential operation between doors A and B is desired t...

Страница 16: ...5 Page 16 TO OPEN PUSH Door 2 Operator Door 1 Operator Door 2 Lock TO OPEN PUSH Inside Wall Switch Door 2 Card Reader Door 2 Power for Lock Power for Lock LOCK DOWN N C N C Magnetic Contact Switch Do...

Страница 17: ...here is a succeeding request on the first door or the door that is already opened it will keep that door opened Potentiometer 5 is useful if the application utilizes locks only and not automatic door...

Страница 18: ...oper voltage and or terminal strip connection Activate an input device to one of the doors Observe the respective output LED which should light immediately The door should unlock and or open If a requ...

Страница 19: ...m 1 to 30 seconds depending on mode selected Electrical Life 100 000 operations rated or 500 000 operations rated capacity In addition to above Model EMF 2 ABM includes a lockable metal cabinet to hou...

Отзывы: