Page 7 of 7

File: CX-EPD1289L Manual.indd 

Rev/Date: 24 March 2023  

Part No.: 40-82B249

Cover plate

flush with

frame 

7

CX-EPD1289L Electric Preload RIM Strike

INSTALLATION INSTRUCTIONS

Other Considerations

 

Although the considerations above will address the majority of installation steps needed for 

a successful installation, there are a few additional items that you will need to check for:

Summary

 

Adherence with the recommendations of this guide will avoid the most common problems 

associated with the installation of RIM strikes. If you require additional assistance, please 

contact our Technical Support department by phone at 1-877-226-2269 or email  

[email protected].

•    

Consideration for deadlocking latch (as shown here). 

 

If exit device has a deadlocking latch, the CX-EPD1289L RIM strike must be mounted so that 

the deadlocking latch does not enter the latch cavity of the RIM strike. Position the strike so 

that the deadlocking latch rests against the face of the strike. 

•    

Consideration of the free movement of the exit device latch and the keeper (jaws) of the 
RIM strike.

 

Ensure the exit device latch and the keeper (jaws) of the electric strike have free and easy 

movement to operate together, with minimum friction. In this, a small amount of silicone 

lubricate on both the latch and jaws of the strike will improve operation. Do not over spray. 

•    

Consideration for a professionally finished retrofit installation. 

 

Replacing electric strikes used with cylindrical or mortise locksets, with an exit device and RIM 

strike, will leave holes in the door and door frame that must be filled or covered. Cover or plug 

holes and check that new cover plates are flush with the frame and will not interfere with 

the RIM strike. 

Содержание CX-EPD1289L

Страница 1: ...15lbs Endurance 1 000 000 Cycles Factory Tested 250 000 Cycles UL Verified Latch Projection 3 4 Fire Rating UL 10C CAN4 S104 3 hrs Fail Secure Only Mode Field Selectable Fail Safe Fail Secure Mechanic...

Страница 2: ...te with the Jamb edge If the door keeper does not align with the template cavity Adjust the template Note 1 Open door slightly Place template on door jamb aligning templates edge with jamb edge Note 1...

Страница 3: ...strike and mark the remaining 2 middle mounting screw positions on frame 5 Open the door and remove the strike from the frame drill and thread the 2 middle mounting screw holes for the 1 4 20 x 1 1 4...

Страница 4: ...input wires Door Status Sensor Closed Position White N O Orange COM Grey N C Red Green Black Blue 12V 24V Black Red Blue Green 12V Varistor 24V Varistor Orange White Grey Black Red 12V 24V Blue Green...

Страница 5: ...e type Fail Secure Type Fail Safe Type Step 4 Setting Fail Secure Fail Safe How to modify fail secure to fail safe or vice versa 1 Remove the cover plate Remove the 6 screws at the front of the electr...

Страница 6: ...common reason for a strike failing Position the RIM strike so that the strike jaws lightly rest against the latch of the exit device Check that the door is not binding on the frame An electric strike...

Страница 7: ...adlocking latch as shown here If exit device has a deadlocking latch the CX EPD1289L RIM strike must be mounted so that the deadlocking latch does not enter the latch cavity of the RIM strike Position...

Отзывы: