background image

 Installation Instructions 

 

 

 

 

 

 

0 = Channel 1 
1 = 1 - 499 = Channel 1, 500 

– 999 = Channel 2 

 
For example 

[*1] 7 # 1 * 

will allocate any user number 

from 1 

– 499 to Channel 1, and any user number from 

500 

– 999 to Channel 2. 

 

[*2] Add/Change/Delete Users 

 

To add or change a user: 
First, enter 

program mode

 (see First Step above), then 

enter  [*2],  then  the  user  number  you  wish  to  add  or 
change (from 1 to 999 inclusive) followed by #. Finally, 
enter the new User Code (up to 8 digits), followed by *, 
then  the  new  User  Code  again  (for  verification), 
followed  by  *.    User  Codes  may  only  contain  digits  0 
through 9 (* and # may not be used as part of the code, 
except 

when programmed as the “enter” key). 

 
Example:   

[*2]  44  #  2125  *  2125  * 

will  assign  a  user 

number of 44 and a user code of 2125. 
 
To delete a user code: 
First,  enter  program  mode.  Then  enter  [*2],  then  the 
user  number  you  wish  to  delete  (from  2  to  999, 
inclusive), then press #, then *, then *. 
For example, 

[*2] 75 # * * 

will delete the user code and 

all assignments for user number 75. 
 
PLEASE  NOTE:  The  Master  Code  cannot  be  deleted 
but it may be changed.  
Example:   

[*2]  1  #  38714  *  38714  * 

will  change  the 

Master Code to 38714. If you change it, don’t forget it. 
 

[*3] Time Delay/Duration Functions 

 
Door Prop open Alarm Delay - Function 2# 
 

Default: Disabled 
Sets  the  delay  (1  to  255  seconds)  before  open  door 
contacts 

are 

considered 

an 

alarm 

condition. 

(

NOTE:

 Door contacts are required for this feature.) 

 
To program the door open alarm delay: 
First,  enter  program  mode.  Then  enter  [*3],  then  2#, 
then the delay time in seconds (0=disabled), then *. 
 
For example, 

[*3] 2 # 30 * 

will set the door open alarm 

delay to 30 seconds. 

NOTE:

 To turn this feature on/off, see section [*4] 3# 

Door Prop Open Alarm on the next page. 
 

 [*4] Alarm Control Functions 

 
Incorrect code alarm - Function 0# 
 

Default: 0 (Disabled) 
Use  to  control  how  the  “Incorrect  code  alarm”  is 
annunciated. 
0 = disabled 
1 = buzzer 
 
If the “Incorrect code alarm” is enabled, and triggered, 
a valid code is required to reset. 
 
To program how the 

“incorrect code alarm” condition is 

annunciated:  
First,  enter  program  mode.  Then  enter  [*4],  then  0#, 
then the annunciation code, then *. 
 
For  example, 

[*4]  0  #  1  * 

will  configure  the  keypad  to 

indicate entry of the programmed count of invalid codes 
on the buzzer only. 
 

Low Battery Alarm - Function 1# 
 

Default: 1 (Enabled) 
Enable or disable the “Low battery alarm”. 
0 = disabled 
1 = buzzer 
To disable the “low battery alarm”: 
First, enter program mode.  (See “First Step” above) 
Enter [*4], then 1#, then the annunciation code, then *. 
 
For example, [*4] 1# 0* will configure the keypad not to 
annunciate the low battery condition. 

 
Stuck key alarm - Function 2# 

 
Default: 0 (Disabled) 
Enable or disable the “Stuck key alarm”. 
0 = disabled 
1 = enable 
The “Stuck key” alarm will activate the buzzer after 15 
seconds  (factory  set  delay)  of  the  key  being  held 
continuously, and reset as soon as the key is released 
(or after 10 seconds, whichever occurs first) 
 
To en

able the “stuck key alarm”: 

First,  enter  program  mode.  Then  enter  [*4],  then  2#, 
then (0 or 1), then *. 
For  example, 

[*4]  2  #  1  * 

will  configure  the  keypad  to 

activate the stuck key buzzer. 
 

Door Prop open Alarm - Function 3# 
 

Default: 0 (Disabled) 
Use  to  control  how  the  “Door  prop  open  alarm”  is 
annunciated. 
0 = disabled 
1 = buzzer 
 

Содержание CM-120TX

Страница 1: ...o terminal 2 Insert the batteries into the battery holder as shown in Figure 1 Figure 1 CM 120TX Power Connections Section 3__________________ How to Program Keypad Using This Manual Brackets and spac...

Страница 2: ...TE A slow flash is once every two seconds and a fast flash is once every second GREEN LED ON Solid No errors output is active FAST FLASHING Keypad is in programming mode RED LED ON Solid Error conditi...

Страница 3: ...abled For example 1 3 0 will disable Force Unique User Codes Backlight Control Enable Disable Function 5 Default 0 disabled Enable or disable backlight control on keypress When enabled the backlight w...

Страница 4: ...ay time in seconds 0 disabled then For example 3 2 30 will set the door open alarm delay to 30 seconds NOTE To turn this feature on off see section 4 3 Door Prop Open Alarm on the next page 4 Alarm Co...

Страница 5: ...usly until reset 6 Annunciation Control Functions Yellow LED Enable Function 0 Default 1 Enabled Enable or disable the yellow LED When enabled the yellow LED illuminates when any key is pressed 0 disa...

Страница 6: ...D s will flash The keypad will immediately move into the battery life indicator It will beep up to 5 times and the green LED will flash Reset the keypad to factory defaults While holding down the and...

Страница 7: ...mand memory will be cleared automatically Start again You will not increment the error count o The Lockout on errors feature is disabled by default This will prevent the keypad from hanging up if anyo...

Страница 8: ...Installation Instructions 8...

Отзывы: