4
—
Specifications
Specifications
Factory
Setting
Factory
Setting
Part Nos.
Part Nos.
Parameter
(Units)
AC Line Input
(VAC ± 10%, 50/60 Hz)
92A61633010000
92A61633020000
92A61633030000
92A61633040000
Horsepower Range HP, (kW)
Armature Voltage Range (VDC)
Current Ranges (ADC)
CL Trimpot Range
(% Range Setting)
MIN Speed Trimpot Range
(% Base Speed)
MAX Speed Trimpot Range
(% Base Speed)
IR COMP Trimpot Range
(% Base Speed)
Speed Range (Ratio)
AC Line Voltage Regulation
(% Base Speed)
Voltage Following Linearity
(% Base Speed)
Load Regulation
(% Base Speed)
Ambient Temperature Range (ºC)
Potentiometer, Front Cover
(ohms – watts)
Maximum Run/Stop Operations
(ops/min)
Enclosure Type (NEMA)
—
115
1/6 – 1, (0.12 – 0.75)
208/230
—
1/3 – 2, (0.25 – 1.5)
1/3, (0.25)
—
1/4, (0.18)
0 – 100
85
0 – 200
170
2, 3.3, 5, 10
3.3
2, 3.3, 5, 10
2
0 – 170
150
0 – 170
150
0 – 30
0
0 – 30
0
60 – 120
100
60 – 120
100
0 – 15
4
0 – 30
8
50:1
—
50:1
± 0.5
—
± 0.5
—
± 0.5
—
± 0.5
—
± 1
—
± 1
—
0 – 45
—
0 – 45
—
5K – 1/3
—
5K – 1/3
—
30
—
30
—
12
—
12
TABLE 2 – GENERAL PERFORMANCE SPECIFICATIONS
100
250
TIME (msec)
DECEL WITH
DYNAMIC BRAKE
MOTOR BASE RATED SPEED
FIXED
ACCEL
SPEED
(rpm)
1800
FIGURE 1 – TYPICAL INDEXING PERFORMANCE
Maximum Cycle
Rate: 30 cycles
per minute with
typical 1 HP motor.
Total reflected
inertia not to
exceed 20% of
armature inertia.
Acceleration time
(fixed at 0.1 sec.)
may be extended
when operating in
Current LImit
Содержание VARI-PAK