Страница 1: ...Manual de usuario traducido TS3 16 2023 01 2022 Cambrionix Ltd Todos los derechos reservados ES...

Страница 2: ...4 4 Conexi n al host 9 4 5 Charging 9 4 6 Cables 10 4 7 Registration 10 4 8 Help and Support 10 5 Using your TS3 16 11 5 0 1 LED Configuration 11 5 1 Using without connecting to host 11 5 2 Using when...

Страница 3: ...5 6 4 Especificaciones f sicas 25 6 5 Informaci n empaquetada 26 6 6 Consumibles y realizaci n de pedidos 26 7 Troubleshooting 28 7 1 Initial troubleshooting tips 28 7 2 Logging through LiveViewer 28...

Страница 4: ...ice charging and synchronisation can be monitored through Cambrionix s LiveViewer Application the Application Programming Interface API or Command Line Interface CLI Cambrionix s free monitoring and c...

Страница 5: ...and safety during operation This user manual cannot cover all possible applications If you would like additional information or if problems arise that are not sufficiently addressed in this manual ple...

Страница 6: ...ad operating instructions Mandatory regulation 3 4 Product modification Cambrionix products are designed and manufactured to meet the requirements of UK and International safety regulations Modificati...

Страница 7: ...N An electric shock or personal injury may occur l Do not use a damaged power cord or plug or a loose power socket l Do not touch the power plug with wet hands l Do not allow liquids to come into cont...

Страница 8: ...your Cambrionix product may occur l Operate the product only in an environment where the ambient temperature is inside the operating temperature range l Operate the product only in an environment whe...

Страница 9: ...and quantities are correct before opening This is to avoid retesting and repackaging any items that are not required When opening the packaging use a suitable method to open the box i e do not use a...

Страница 10: ...o puede dar lugar a que el hub y todos los puertos posteriores no sean reconocidos por su host Cambrionix would recommend using the Thunderbolt cable that is provided with our TS3 16 Si est consideran...

Страница 11: ...he cable that was provided with the device to connect to our hubs 4 7 Registration You may register your product at www cambrionix com product registration 4 8 Help and Support FAQs and help can be fo...

Страница 12: ...s switched on and is not connected to a local host computer it is automatically configured to charge devices using its intelligent charging algorithm Connect the devices to be charged to any of the av...

Страница 13: ...patibles cuentan con una interfaz para forzar la alimentaci n sistemas compatibles hay una interfaz para forzar la alimentaci n del controlador Thunderbolt Si se admite este comando solicitar al daemo...

Страница 14: ...g 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 reboot This can also be done via the API if this is easier Just supply that string joined with n like cbrxapi cbrx_connection_set handle settings settings_unlock nset...

Страница 15: ...n The TS3 16 appears as a virtual serial port also called a UART or VCP En Microsoft Windows el sistema aparecer como un puerto COM el n mero de puerto COM se puede encontrar en el administrador de d...

Страница 16: ...rporar controladores de host dentro del hub cada puerto puede manejar hasta 16 puntos de conexi n If you wish to synchronise more devices multiple hubs can be daisy chained to allow up to 96 devices t...

Страница 17: ...ost system If you are in Sync mode and then switch to Charge mode the USB device will disconnect briefly whilst the profiling process takes place Once the profiling has taken place and a charging prof...

Страница 18: ...6 2 4A Typically used by Apple 5 4 4 Firmware The firmware can be kept up to date using our LiveViewer software As part of delivering an easy user experience our LiveViewer application is now a set a...

Страница 19: ...ce Firmware versions and hardware We advise not to change the firmware version on any new products you receive as this may cause compatibility issues and stop your TS3 16 from functioning PRECAUCI N Y...

Страница 20: ...a bug that we have a fix for the Alpha and Beta releases may already have addressed these and implemented fixes 5 5 1 Installing Software Cambrionix has two pieces of software that can be used to man...

Страница 21: ...rt is in Charge mode the charge profile current energy rate charge duration and end time are displayed In addition to individual port information and control LiveViewer shows the hub rail voltages tim...

Страница 22: ...ion and control can be provided through the API Calls are sent as a request to the API to Get port device or Hub information or Set port functions such as mode A library of sample code can be obtained...

Страница 23: ...to Add or remove programs finding the software you wish to remove selecting it and pressing uninstall macOS To remove the software from a macOS system locate the application in the Finder drag the app...

Страница 24: ...l the installed packages that match those letters at the beginning of their names 5 5 6 Command Line Instructions CLI Command Line Instructions can be used to control and monitor the functions of the...

Страница 25: ...to est apagado y de que el cable de alimentaci n se haya desconectado del producto Sostenga el cable de alimentaci n junto al enchufe y no toque el enchufe ni el cable de alimentaci n con las manos mo...

Страница 26: ...salida 5 0 V 5 Corriente de salida m x por puerto 2 4 A Potencia de salida m x por puerto 12 W Potencia de salida total 230 W 6 3 Valores de riel de bandera de error Riel de cinco voltios m x 5 58 V...

Страница 27: ...5A 250V Cables 16 x USB 3 2 tipo A If you require any spare parts such as the power cables or Thunderbolt 3 cable these can be ordered by quoting the product part number and the spare part number avai...

Страница 28: ...TS3 16 P gina 27 de 38...

Страница 29: ...r if this is not already downloaded then go onto our website and download both the API and LiveViewer www cambrionix com software 2 Once in LiveViewer on the left hand side of the screen select the se...

Страница 30: ...ngs either by going through the advanced settings and turning Sync charge off or through the API and disabling it via code For example the instructions would be below using the command line settings_u...

Страница 31: ...sitivo en la conexi n inicial Esto tambi n podr a deberse a una cantidad insuficiente de puntos finales disponibles en el controlador USB en el sistema host Esta limitaci n dentro del controlador USB...

Страница 32: ...E mark type C cables may not work on the daisy chain when connecting the expansion port to another PDysnc 4 We recommend to use passive type C cables and not to use cables fitted with e markers see yo...

Страница 33: ...onix cambrionix log cfg 7 7 Software troubleshooting Some users have noted that the API can cause a high level of CPU usage This can sometimes be linked to the API recorder service If you are finding...

Страница 34: ...the Council of the European Union on the waste electrical and electronic equipment WEEE and in jurisdictions adopting that Directive is marked as being put on the market after August 12 2005 and shoul...

Страница 35: ...the delivery note detailing this 9 2 What happens after I have requested a Return l If you have not purchased the Product s direct from Cambrionix please contact the vendor the item was originally pur...

Страница 36: ...l Probado y marcado CE l Probado y marcado seg n la Parte 15 de la FCC l Alojado en una envolvente a prueba de incendios de la especificaci n UL94 VO l Cumplimiento de RoHS l Probado independientement...

Страница 37: ...rademarks service marks and other protected names and or symbols contained in this manual and related documents are the property of their respective holders Mac and macOS are trademarks of Apple Inc r...

Страница 38: ...D IT 90079186690001 007918669 0001 90079186690001 MOD IT 90079186690002 007918669 0002 90079186690002 MOD IT 90079186690003 007918669 0003 90079186690003 MOD IT 90079186690004 007918669 0004 900791866...

Страница 39: ...a6ebe915fe9 202012310 202012310 MOD IT MM 195758 MOD IT MM 329441 001 MOD IT MM 29 735 479 MOD IT 6077256 6077256 6077256 MOD IT STACK 6077257 6077257 6077257 MOD IT STACK 081a4b9c69eb 202012312 20201...

Страница 40: ...ad Cambridge CB4 0DS Reino Unido 44 0 1223 755 520 enquiries cambrionix com www cambrionix com Cambrionix Ltd es una empresa registrada en Inglaterra y Gales con el n mero de empresa 06210854 2023 01...