4)

 

To update the 

Main Fir

mware’ 

select 

‘C

hoose File

 to find the 

correct .tar file. Once selected click 

the ‘Update’ button

Please check the instructions 
provided with the update when it is 
downloaded from Cambrionix

website as an alternative procedure 
may be used such as using an SD 
card. 

 

 

 

 

 

5)

 

A successful update will automatically reboot the EtherSync, however this can be done 
manually by going to the bottom of 

System>>Boot up and Shutdown

. Once this has 

happened it is ready to use. 

 

 

 

 

 

The 2

nd

 Gigabit Ethernet port allows extension of the network 

in a ‘daisy

-

chain’

 to other devices, such as 

additional EtherSyncs or computers. This is especially useful in situations where EtherSync is to be inserted 
into an existing networked location or if more than one EtherSync is being used in close proximity. 

 

EtherSync can also be connected to other Cambrionix products. 

[Please note the daisy chaining of hubs 

requires additional power supplies]

. For more information on this please contac[email protected]  

 

Items required to ‘daisy

-

chain’ several EtherSyncs:

 

 

2 or more EtherSync units 

 

2 or more RJ45 to RJ45 Ethernet cables 

 

2 or more Power Supplies 

[each EtherSync will need its own power supply] 

 

 

1)

 

Connect the power to all EtherSyncs required in the ‘chain’

 
 

2)

 

Connect the first EtherSync to the network via the RJ45 to RJ45 Ethernet cable

 
 

3)

 

Connect another EtherSync using a second RJ45 Ethernet cable by inserting one end into 
the first EtherSync and the other end into the second EtherSync. You can repeat this step 
with a third and subsequent EtherSyncs

 
 

NOTE 
Do not form a loop of EtherSyncs by connecting the last EtherSync in the chain to the 
network port. 

 

 

 

 

 

Содержание EtherSync

Страница 1: ......

Страница 2: ...page 2 of 17 EtherSync User Guide document revision 1 01 3 4 5 5 6 6 8 8 10 11 12 12 12 13 13 15 17 17 ...

Страница 3: ... light when EtherSync has access to the internal Memory Also used as the locator LED via the Webmin interface This LED can be illuminated or made to blink to locate the EtherSync that is currently being used via the Webmin interface LED may not be illuminated at its maximum brightness this is normal the brightness will increase as more devices are charged by EtherSync It may also flicker which is ...

Страница 4: ...otal 96W Output Connector 4 pin Mini DIN EtherSync Input Voltage 12V DC Input Current 8A Input Connector 4 pin Mini Din Output Voltage 5 2V Output Current 2 1A Max per Port Output Power Total 88W Maximum Input Output Connectors 8 x USB A Receptacle 2 x Gigabit RJ45 Ethernet ports 1 x SD Card connector Dimensions approx 130 long x 105 wide x 40 high mm The 4 pin Mini DIN polarity required for use w...

Страница 5: ...G type plug for the UK A standard RJ45 to RJ45 Ethernet cable EtherSync Connector Software downloadable from https hub cambrionix com pages ethersync 1 Push the 4 pin Mini DIN from the power supply into the EtherSync s power input 2 Insert the C13 connector into the C14 receptacle on the power supply 3 Taking necessary precautions turn on the mains power ...

Страница 6: ...rts 2 Connect the other end to an Ethernet network with an active DHCP Dynamic Host Configuration Protocol server which will automatically assign an IP address to EtherSync NOTE Depending on your network you may need to configure the connection 3 If you need to configure the parameters or host name of your network connection the default hostname for EtherSync is EtherSync followed by the last 6 di...

Страница 7: ... password with the password box empty do not select No password accepted The password for LiveViewer will stay the same i e the initial password located on the back of the EtherSync 5 From the left box select Networking then Connection Manager 6 From here you can set up the address DHCP for network interfaces or select the Ethernet Port by selecting Network Interface and give the EtherSync a host ...

Страница 8: ... reset to factory settings This means that the name webmin username and password are as described above To download the EtherSync Connector Software go to https hub cambrionix com pages ethersync and follow the on screen instructions For OS X it is the dmg file for Windows it is either the 32 or 64 bit application depending on your system The application will not close if the X is clicked Instead ...

Страница 9: ...as the client computer and open the EtherSync Connector application 4 Click on the symbol to expand the USB Hub list displaying all EtherSyncs connected to the network 5 Click the sign next to the EtherSync called EtherSyncXXYYZZ where XXYYZZ are the last 6 digits of the Mac address to display the devices connected to that EtherSync Note It is possible to rename an EtherSync by right clicking on t...

Страница 10: ...atically uses the device no matter what port it is connected to Note All devices connected to an EtherSync can be automatically used by right clicking on the desired EtherSync and selecting Auto Use Devices on Hub 7 The operating system will install the correct driver if needed for the device in Use 8 The devices connected to the EtherSync will now appear on the client computer as if they are conn...

Страница 11: ...tically used by right clicking on the desired EtherSync and selecting Auto Use Devices on Hub 5 The devices will now appear on the client computer as if they are connected directly By default EtherSyncs will appear on the Connector Software as EtherSyncXXYYZZ where XXYYZZ are the last 6 digits of the Mac Address which can be found on the bottom of the EtherSync The Custom Event Handler option in t...

Страница 12: ... 6 2 Go to Hardware LED Control To turn on the LED select Locator On or Locator Blink To turn off the Locator LED select Locator Off Cambrionix periodically releases updates to the firmware which is used on all current Cambrionix products To update EtherSync 1 Open the Webmin interface and logon using the details listed in section 4 1 2 Click the System tab on the left of the window then Cambrioni...

Страница 13: ... into an existing networked location or if more than one EtherSync is being used in close proximity EtherSync can also be connected to other Cambrionix products Please note the daisy chaining of hubs requires additional power supplies For more information on this please contact support cambrionix com Items required to daisy chain several EtherSyncs 2 or more EtherSync units 2 or more RJ45 to RJ45 ...

Страница 14: ...or your operating system which can be downloaded from https hub cambrionix com pages upda ter 4 The connected hubs should now be displayed on the middle of the window If they are not click the Scan button The application should find all connected hubs 5 Tick the boxes next to the hubs that need their firmware upgrading If more than one hub is connected un tick the box next to the boards that do no...

Страница 15: ...e shooting guide which can be found at http www cambrionix com returns policy This is a guide to some of the simple issues that may occur Since EtherSync is more complex than other USB hubs there may be something else causing a problem If the above solutions do not help please see below In all instances listed below if a problem persists after these solutions contact support cambrionix com with as...

Страница 16: ... not displayed in the EtherSync Connector application Make sure Auto Find Hubs is selected from the contextual menu in the EtherSync Connector application Ensure that the desired EtherSync is connected to the same subnet as the host computer or set up a network connection to the desired EtherSync as described in section 4 2 Download the most up to date Connector application from https hub cambrion...

Страница 17: ...omplies with the relevant safety standards to be C UL US Listed File number E346549 Waste Electrical and Electronic Equipment Directive WEEE 2002 96 EC When this product is no longer required if it cannot be re used we ask our customers not to dispose of it as unsorted municipal waste but to appropriately recycle the product or return it to Cambrionix Ltd for correct disposal Full FCC statement Th...

Отзывы: