Introduction 

Planning for a Cambridge Elevating Home Elevator 

Provisions by Others 

Description of Elevator Equipment 

Hoistway Construction – General Notes 

Hoistway Construction – Wood Stud Wall 

Hoistway Elevation – Overhead Requirements 

Pit Details 

Machine Room Details – General Layout 

Machine Room Details – Controller / Pump Details 

Cambrian Landing Frame Details - Elevation 

Cambrian Landing Frame Details - Layout 

 

Drawings - 

Elmira Model Cab/Hoistway Size Layout

 

Drawings - Heritage Model Cab/Hoistway Size Layout

 

Drawings - Cambrian Model Cab/Hoistway Size Layout

 

Elevator Specifications for ASME A17.1 Part V Compliance

 

14-15

1

6

1

7

1

8

-2

1

Содержание Cambrian

Страница 1: ...Residential Elevator Design Guide All Models Elmira Heritage Cambrian 1261 Industrial Rd Cambridge ON N3H 4W3 p 1 800 265 3579 p 519 653 4222 fl 519 653 9927 www CambridgeElevating com ...

Страница 2: ...ruction Wood Stud Wall Hoistway Elevation Overhead Requirements Pit Details Machine Room Details General Layout Machine Room Details Controller Pump Details Cambrian Landing Frame Details Elevation Cambrian Landing Frame Details Layout Drawings Elmira Model Cab Hoistway Size Layout Drawings Heritage Model Cab Hoistway Size Layout Drawings Cambrian Model Cab Hoistway Size Layout Elevator Specificat...

Страница 3: ... to change without notice Planning for a Cambridge Elevating Home Elevator The following planning procedure is strongly recommended 1 Determine the customer s intended use 2 Determine the customer s desired convenience level with respect to model type Elmira swing landing door with manual or automatic accordion cab gate Heritage swing landing door with automatic sliding cab door panels Cambrian au...

Страница 4: ...Cambrian Landing Frame Details see page 12 Provide required rough openings at each hoistway landing as per elevator manufacturer s engineered drawings Provide sufficient machine room area suitable to contain hydraulic power unit and elevator controller disconnect based on elevator manufacturer s engineered drawings Provide telephone connection to outside line for integration into elevator controll...

Страница 5: ...ige or s s Automatic sliding landing door panels beige or s s Controls Microprocessor controller with relays for basic operation Fully automatic operation Automatic timed cab lighting Stainless steel car operating panel COP telephone box and hall call stations Dual illuminated hall call station push buttons and position indicating push buttons on COP Emergency stop switch on COP LED dot matrix Dig...

Страница 6: ...tructure must sustain a chain hoist for hoisting elevator materials to the top of the hoistway during installation A structural engineer must ensure that building and hoistway can safely support all loads imposed by the elevator equipment The drawings contained herein have been prepared using engineering principles and the design loads that are applied by the rails to the wall However the details ...

Страница 7: ...WO 2 x 12 INSIDE TWO 2 x 6 2x6s SCREWED TO 2x12s EVERY 6 WITH 10x3 1 2 WOOD SCREWS CHANNELS AND MIDDLE STUDS BETWEEN FLOORS FULL HEIGHT OF HOISTWAY MIDDLE STUDS THREE 2 x 6 3 4 PLYWOOD DOOR WALL CAMBRIDGE ELEVATING IS NOT RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE BUILDING AND ITS ABILITY TO SUPPORT THE ELEVATOR LOADS AND OR REACTIONS R1 720LBS R2 225LBS R3 720LBS WWW CAMBRIDGEELEVATING COM CAMB...

Страница 8: ......

Страница 9: ... PIT FLOOR TO BE MADE OF MINIMUM 15MPa CONCRETE 4 0 MINIMUM 12 FOR HERITAGE OR CAMBRIAN 8 MIN ELMIRA SECTION A A FINISH BASEMENT WWW CAMBRIDGEELEVATING COM CAMBRIDGE ONTARIO THIS DRAWING AND THE INFORMATION IT CONTAINS ARE PROPRIETARY TO CAMBRIDGE ELEVATING INC THIS DOCUMENT MUST NOT BE DUPLICATED OR ITS CONTENTS USED OR DISCLOSED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION FROM CAMBRIDGE E...

Страница 10: ...rdance with all codes and regulations A 220 VAC 60 Hz 30 Amp single phase power source in the machine room to be provided A 115 VAC 60 Hz 15 Amp single phase power source in the machine room to be provided A telephone line circuit to be provided if required This circuit must be connected to an outside line ...

Страница 11: ...EMA 5 15P PLUG PUMP DISCONNECT 240VAC 30 AMP NEMA 14 30P PLUG 8 1 2 HYDRAULIC POWER UNIT BES3 RESIDENTIAL PUMP CONTROLLER DETAILS WIRE GAUGE AS PER LOCAL CODE REQUIREMENTS USUALLY MOUNTED IN MECHANICAL ROOM ON WALL WITHIN 6 OF HYDRAULIC POWER UNIT OR TO STRUTS MOUNTED ON REAR OF PUMP TANK OUTLETS TO BE SUPPLIED BY G C WITHIN 36 OF THE CONTROLLER ON THE RIGHT SIDE REQUIRES NEMA 5 15 OUTLET AT 60 HI...

Страница 12: ...ng to leave door walls wide open for installation Landing door jambs and header fit within rough stud opening Landing door operating mechanism door frames and sill hang in hoistway attached to inside wall of hoistway using brackets Drawing below depicts view from landing looking into elevator hoistway rails support on right wall ...

Страница 13: ...www CambridgeElevating com August 2017 13 Cambrian Landing Frame Details Layout It is the recommendation of Cambridge Elevating to leave door walls wide open for installation ...

Страница 14: ...66 25 31 31 25 40 x 48 58 x 54 25 35 26 75 40 x 54 58 x 60 25 35 28 25 Please note dimensions remain for mirrored configurations TYPE 1 INLINE Cab Size Centerlines Hoistway Size Width x Depth Landing Door Rail Wall 36 x 48 54 x 50 5 31 24 25 36 x 54 54 x 56 5 31 27 25 36 x 60 54 x 62 5 31 31 25 40 x 48 58 x 50 5 35 24 25 40 x 54 58 x 56 5 35 27 25 Please note dimensions remain for mirrored configu...

Страница 15: ...7 48 x 42 58 x 56 25 35 29 54 x 48 64 x 62 25 41 32 60 x 48 70 x 62 25 47 35 Please note dimensions remain for mirrored configurations TYPE 5 INLINE Cab Size Hoistway Size Centerlines Width x Depth Landing Door Rail Wall 36 x 48 51 75 x 54 25 28 5 25 25 40 x 60 55 75 x 66 25 33 31 25 48 x 48 63 75 x 54 25 40 5 25 25 48 x 60 63 75 x 66 25 40 5 31 25 Please note dimensions remain for mirrored config...

Страница 16: ... 54 x 70 5 32 75 34 0625 40 x 54 3 panel doors 58 x 62 5 34 75 31 0625 Please note dimensions remain for mirrored configurations TYPE 1 INLINE Cab Size Hoistway Size Centerlines Width x Depth Landing Door Rail Wall 44 x 48 2 panel doors 62 x 58 5 38 75 29 25 36 x 48 3 panel doors 54 x 59 75 32 75 29 875 36 x 60 3 panel doors 54 x 71 75 32 75 35 875 40 x 54 3 panel doors 58 x 65 75 34 75 32 875 Ple...

Страница 17: ...oors 54 x 75 25 32 75 39 40 x 54 3 panel doors 58 x 69 25 34 75 36 Please note dimensions remain for mirrored configurations TYPE 1 INLINE Cab Size Hoistway Size Centerlines Width x Depth Landing Door Rail Wall 44 x 48 2 panel doors 62 x 65 75 38 75 32 75 36 x 48 3 panel doors 54 x 68 5 32 75 34 25 36 x 60 3 panel doors 54 x 80 5 32 75 40 25 40 x 54 3 panel doors 58 x 74 5 34 75 37 25 Please note ...

Страница 18: ...or and Escalator Electrical Equipment 1 4 3 ICC ANSI A117 1 1998 Accessible and Usable Buildings and Facilities 1 4 4 NFPA 70 1999 National Electric Code 1 4 5 ADAAG Americans with Disabilities Act Accessibility Guidelines PART 2 PREPARATORY WORK BY OTHERS 2 1 Hoistway Provide an enclosed plumb and square hoistway with smooth interior surfaces Provide fascias or furring of hoistway interior where ...

Страница 19: ...able please consult your authorized dealer or CE sales representative A minimum cab width of 44 is required for 2 speed panel doors 4 2 1 2 Cab Configuration Inline enter exit same side 90 degree or straight thru layouts available 4 2 1 3 Cab Construction Metal bracket and or tubular frame structure with melamine veneer stainless steel or laminate finish panels Ceiling white melamine or to match w...

Страница 20: ...ower outages 4 2 4 Cylinder Single stage jack with line rupture valve 750 psi working pressure 4 2 5 Ropes Two 3 8 diameter 9 x 17 wire ropes 4 2 6 Guide rail Dual 8 lb steel modular T rail system 4 2 7 Car Sling The elevator cab shall be supported by the car sling The car sling shall be made of structural and formed steel and equipped with guide rollers and Type A roller safeties complete with sl...

Страница 21: ...in cab 4 2 9 14 Phone in cab PART 5 EXECUTION 5 1 Examination All site dimensions and conditions shall be verified to ensure they meet specifications codes and regulations 5 2 Installation Confirm that all site dimensions and conditions match those specified on shop drawings Do not proceed with installation if the site dimensions and conditions are not acceptable Elevator shall be installed by tra...