11

 

 

 

The  applicable  ISEDC  power  density  exposure  limit  for  RF  energy  in  unlicensed  bands  is  0.02619  *  (f^ 
(0.6834)), where f is the lowest frequency of the supported band. For licensed bands, the power density 
exposure limit is 0.6455 * (f^ (0.5)), where f is the lowest frequency of the supported band. 

Calculation of power density and distance 

The following calculation is based on the ANSI IEEE C95.1-1991 method, as that it provides a worst-case 
analysis. Details of the assessment to EN50383:2002 can be provided, if required. 

Peak power density in the far field of a radio frequency point source is calculated as follows: 

 

 

 Maximum average transmit power capability of the radio, in W 

 total Tx gain as a factor, converted from dB 

 power density (W/m²) 

 Distance from point source, in cm (Centimeters) 

Table 3 Antenna details 

AP 

Antenna 

Gain (For 2.4 GHz in dBi) 

Gain (For 5 GHz in dBi) 

XV3-8 

Omnidirectional  

5.1 

6.7 

XV2-2 

Omnidirectional 

5.4 

6.3 

For details on minimum safe distance value, please refer Table 4

.

 

Calculated distances and power compliance margins 

Table 4 displays power density and minimum safe separation distance from point source for each 

frequency band and antenna combination for the USA and Canada. These are conservative distances 

that include compliance margins.  

Cambium  Networks  Enterprise  Wi-Fi  AP  adheres  to  all  applicable  EIRP  limits  for  transmit  power  when 

operating in MIMO mode. Separation distances and compliance margins include compensation for both 

transmitters. 

 

 

Explanation of terms used in the following tables: 

 maximum average transmits power of the radio (Watt) 

 total transmit gain as a factor, converted from dB 

 power density (W/m²) 

 minimum safe separation distance from point source (Centimeters) 

2

4

.

d

G

P

S

=

S

G

P

d

.

4

.

=

Содержание XV3-8

Страница 1: ...ms stored in semiconductor memories or other media Laws in the United States and other countries preserve for Cambium its licensors and other 3rd Party supplied software certain exclusive rights for c...

Страница 2: ...s of the copyrighted material Accordingly any copyrighted material of Cambium its licensors or the 3rd Party software supplied material contained in the Cambium products described in this document may...

Страница 3: ...USA and Canada specific information 6 Federal Communication Commission interference statement 6 Specific expertise and training required for professional installers 7 Avoidance of weather radars 7 Eth...

Страница 4: ...Enterprise Wi Fi AP Hardware Installation Guide List of Figures 2 List of Figures Figure 1 Grounding and lightning protection on pole or tower 9 Figure 2 Grounding and lightning protection on wall 10...

Страница 5: ...ardware Installation Guide List of Tables 3 List of Tables Table 1 Related documents 2 Table 2 Hardware platforms 3 Table 3 Antenna details 11 Table 4 Power density and distance 12 Table 5 Types of mo...

Страница 6: ...etting Up and configuring Cambium Network s AP Intended audience This guide is intended for use by the system designer system installer and system administrator Purpose Cambium Network s AP documents...

Страница 7: ...Tri Radio indoor Access Point XV2 2 2x2 2 2x2 2 802 11a b g n ac wave 2 ax Dual Radio indoor Access Point Reporting problems security advice and safety and regulatory information This section includes...

Страница 8: ...ion This section describes important safety and regulatory guidelines that must be observed by personnel installing or operating Enterprise Access Point equipment Important safety information Warning...

Страница 9: ...inal penalties Contact the Cambium helpdesk if more guidance is required Human exposure to radio frequency energy Relevant standards USA and EC applicable when working with RF equipment are ANSI IEEE...

Страница 10: ...ferent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Attention Any changes or modifications not expressly approved by the party respons...

Страница 11: ...ould be installed and operated with minimum distance 20 cm between the radiator and your body Cet quipement est conforme aux limites d exposition aux rayonnements IC tablies pour un environnement non...

Страница 12: ...llow the below requirements Ensure that the position of the equipment is lower than the top of the tower or its lightning air terminal Ensure that the metal tower or pole is correctly grounded Install...

Страница 13: ...need to install AP on the wall of a building then in addition to the general protection requirements follow the below requirements also Ensure that the position of the equipment is lower than the top...

Страница 14: ...works Enterprise Wi Fi AP must be gained by reading this User Guide and by performing sample setups at base workshop before live installments Power density exposure limit This section includes the fol...

Страница 15: ...m d Distance from point source in cm Centimeters Table 3 Antenna details AP Antenna Gain For 2 4 GHz in dBi Gain For 5 GHz in dBi XV3 8 Omnidirectional 5 1 6 7 XV2 2 Omnidirectional 5 4 6 3 For detai...

Страница 16: ...This User Guide 12 Table 4 Power density and distance Product Regulatory Domain Power density S mW cm Distance d cm XV3 8 FCC 0 21 0 33 31 IC 0 22 0 35 30 CE 0 197 7 47 2 4G 5G W m 20 XV2 2 FCC 0 45 0...

Страница 17: ...um Networks Enterprise Wi Fi AP sales representative Package contents A complete Cambium Networks Enterprise Wi Fi AP package contains all the items listed below 1 Cambium Networks Enterprise Wi Fi AP...

Страница 18: ...oint Wall Mount Ceiling Mount T bar Mount XV3 8 XV2 2 Mounting XV3 8 Ceiling Mount 1 Determine where XV3 8 needs to be mounted and remove the ceiling tile 2 Using the hole template mark the hole locat...

Страница 19: ...on the mounting bracket 6 Run the RJ45 cable cables through the 15mm hole and remount the ceiling tile 7 Attach the RJ45 cable cables to XV3 8 8 Slide XV3 8 into the mounting bracket Wall Mounting The...

Страница 20: ...bar rail by using the ceiling mount bracket The A marking on the bracket is to be used for this width T bar rail 24mm T Bar The XV3 8 can be mounted to a 24mm width T bar rail using the clips built i...

Страница 21: ...nd Installation of Access Point 17 14mm T Bar The XV3 8 can be mounted to a 14mm width T bar rail using the clips built into the underside of the unit The C marking on the bracket is to be used for th...

Страница 22: ...rill the holes for the 4 mounting screws using a 5mm 3 6 diameter drill bit 4 Drill the RJ45 cable hole using a 15 mm 5 8 diameter bit 5 Hold the mounting plate on the top side of the ceiling tile and...

Страница 23: ...screws with corresponding wall anchors The ceiling mount bracket can be used as a template to align the screws with the unit T bar Mounting 38mm T Bar The XV2 2 can be secured to a 38mm ceiling T bar...

Страница 24: ...s built into the underside of the unit The B marking on the bracket is to be used for this width T bar rail 14mm T Bar The XV2 2 can be mounted to a 14mm width T bar rail using the clips built into th...

Отзывы: