phn-4026 003v000
Page 4-1
Chapter 4:
Cable Installation and
Grounding
List of Items
Table 10
Required items for cable installation and grounding
Item Description
Quantity
Remarks
1
Cable Grounding Kits For 1/4" And 3/8"
Cable (P/N 01010419001)
1
Procedure
1
On the front side of each RFU-C unit, loosen the nut, plain washer, and serrated washer.
2
Place the cable lug (supplied with the RFU-C grounding kit) on the screw.
3
Secure the cable lug.
Figure 2
RFU-C Grounding Cable
•
The unit’s earthing screw terminal shall be permanently connected to protective earth in a building
installation in accordance with applicable national code and regulations by a service person.
•
A 2-Pole circuit breaker, a branch circuit protector, suitably certified in accordance with applicable
national code and regulations, rated maximum 20A, shall be installed for full power disconnection in a
building installation.
•
Any outdoor antenna cable shield shall be permanently connected to protective earth in a building
installation.