Chapter 10: Alarm Management and Troubleshooting
Performing Diagnostics
phn-3963_008v000
Page 10-29
Figure 178
SOAM MEP DB Table
lists and describes the parameters displayed in the SOAM MEP DB table. To return to the SOAM MEP
page, click
Back to MEP
.
Table 49
SOAM MEP DB Table Parameters
Parameter
Definition
RMEP ID
The remote MEP ID.
RMEP Operational State
The operational state of the remote MEP.
RMEP Last rx CCM MAC
Address
The MAC Address of the interface on which the remote MEP is located.
RMEP Last CCM OK or Fail
Timestamp
The timestamp marked by the remote MEP indicated the most recent
CCM OK or failure it recorded. If none, this field indicates the amount of
time since SOAM was activated.
RMEP Last rx CCM RDI
Indication
Displays the state of the RDI (Remote Defect Indicator) bit in the most
recent CCM received by the remote MEP. If none, displays
False
.
RMEP Last rx CCM Port
Status TLV
The Port Status TLV in the most recent CCM received from the remote
MEP. Reserved for future use.
RMEP Last rx CCM
Interface Status TLV
Displays the operational status of the interface on which the remote MEP
has been defined.
RMEP Last rx CCM Chassis
ID Format
Displays the MAC addressformat of the remote unit.chassis (always the
MAC address).
RMEP Last rx CCM Chassis
ID
Reserved for future use.Displays the MAC address of the remote chassis.
Displaying Last Invalid CCMS
To display the entire frame of the last CCM error message and the last CCM cross-connect error message received
by a specific local MEP:
1.
Select
Ethernet > Protocols > SOAM > MEP
. The SOAM MEP page opens (