I nst alling t he I F and ground cables
Chapt er 5: I nst allat ion
5- 58
phn- 2513_004v000 ( Oct 2012)
1 0
Clamp the bottom lug of the grounding cable to the supporting structure using
site approved methods.
Use a two-hole lug secured with fasteners in both holes. This provides better
protection than a single-hole lug.
Installing and grounding the IF cable at building entry
Perform this procedure to install and ground the IF at the building (or cabinet) entry point
(
Figu r e 7 9
Gr ounding at building ent ry