3 Fit the RJ45 connector housing as shown. To ensure there is effective strain relief, locate
the cable inner sheath under the connector housing tang:
4 Repeat steps 1 to 3 to fit an RJ45 connector and cable gland at the other end.
Installing the main drop cable
Install the main drop cable from the top to the bottom LPU.
Warning
Failure to obey the following precautions may result in injury or death:
•
Use the hoisting grip to hoist one cable only. Attempting to hoist more than one cable may
cause the hoisting grip to break or the cables to fall.
•
Do not use the hoisting grip for lowering cable unless the clamp is securely in place.
•
Maintain tension on the hoisting grip during hoisting. Loss of tension can cause dangerous
movement of the cable and result in injury or death to personnel.
•
Do not release tension on the grip until after the grip handle has been fastened to the
supporting structure.
1 Hoist the top end of the main drop cable up to the top LPU, following the hoist
manufacturer’s instructions. When the cable is in position, fasten the grip handle to
the supporting structure and remove the hoist line.
2 Connect the main drop cable to the top LPU by following the procedure
Connecting a
drop cable to the ODU and LPU
on page
20
.
3 Make an entry point into the equipment building and run the main drop cable to the
site of the bottom LPU.
4 Attach the main drop cable to the supporting structure using site approved methods.