PMP Synchronization Solutions User Guide
Configuring a CMM4
PMP-0297 007v001 (January, 2017)
3-39
Attribute
Meaning
Site Name
Enter a name for the physical module. What you enter here will be shown
on the General Status tab in the Home page of the CMM4. This
information is also set into the
sysName
SNMP MIB-II object and can be
polled by an SNMP management server.
Site Contact
Enter contact information for the physical module. What you enter here
will be shown on the General Status tab in the Home page of the CMM4.
This information is also set into the
sysName
SNMP MIB-II object and can
be polled by an SNMP management server.
Site Location
Enter site information for the physical module. What you enter here will be
shown on the General Status tab in the Home page of the CMM4.
Configuring VLAN
An example of the CMM4 802.1Q VLAN tab is displayed in
Figure 42 VLAN tab of CMM4
The VLAN tab provides the following parameters.
Table 19 VLAN tab attributes
Attribute
Meaning
Enable VLAN
Tagging
If this parameter is set to Enabled and a Management VLAN ID is set in the
next parameter, then the controller board’s management interface will accept
only frames that are VLAN tagged with the configured tag value. All frames
outgoing from the management interface will have a VLAN tag, set to the
configured VLAN ID.
Management
VLAN ID
If Enable VLAN Tagging is set to Enabled and this parameter is set, then the
management interface will accept only frames that are VLAN tagged with the
configured tag value. All frames outgoing from the management interface of
the CMM4 will have a VLAN tag, set to the configured Management VLAN ID.