PMP 450 Planning Guide
Calculating Link Loss
The link loss is the total attenuation of the wireless signal between two point-to-multipoint units. The link loss
calculation is presented below:
Link Loss (dB) = Transmit power of the remote wireless unit (dBm)
− Tx Cable loss (dB) − Received
power at the local unit (dBm) – Rx cable loss (dB) + Antenna gain at the remote unit (dBi) + Antenna gain at
the local unit (dBi)
Calculating Rx Signal Level
The Rx sensitivity of each module is provided at
http://www.cambiumnetworks.com
. The determinants in Rx signal
level are illustrated in Figure 17
Figure 17 Determinants in Rx signal level
Rx signal level is calculated as follows:
Rx signal level dB = Tx power
− Tx cable loss + Tx antenna gain
− free space path loss + Rx antenna gain − Rx cable loss
This Rx signal level calculation presumes that a clear line of sight is established between the transmitter and
receiver and that no objects encroach in the Fresnel zone.
pmp-0047 (March 2014)
1-93
Содержание PMP 450
Страница 1: ...Cambium PMP 450 Planning Guide System Release 13 1 ...
Страница 13: ...PMP 450 Planning Guide pmp 0047 March 2014 1 3 ...
Страница 30: ...PMP 450 Planning Guide Radio tab of the AP Figure 8 Radio tab of the AP 1 20 pmp 0047 March 2014 ...
Страница 41: ...PMP 450 Planning Guide Radio tab of the SM Figure 13 Radio tab of the SM pmp 0047 March 2014 1 31 ...
Страница 42: ...PMP 450 Planning Guide Figure 14 Custom Frequency tab of the SM 1 32 pmp 0047 March 2014 ...
Страница 58: ...PMP 450 Planning Guide Figure 16 AP web based management screenshot 1 48 pmp 0047 March 2014 ...
Страница 82: ...PMP 450 Planning Guide 1 72 pmp 0047 March 2014 ...
Страница 155: ...PMP 450 Planning Guide pmp 0047 March 2014 1 145 ...