Chapter 4: Reference information
Equipment specifications
Page
4-54
PSU specifications
The PMP/PTP 450i AC+DC Enhanced Power Injector conforms to the specifications listed in
Table 166 PMP/PTP 450i AC power Injector specifications
Category
Specification
Dimensions
137 mm (5.4 in) x 56 mm (2.2 in) x 38 mm (1.5 in)
Weight
0.240 Kg (0.5 lbs)
Temperature
-40°C to +60°C
Humidity
90% non-condensing
Waterproofing
Not waterproof
Altitude
Sea level to 5000 meters (16000 ft)
AC Input
Min 90 V AC, 57 – 63 Hz, max 264 V AC, 47 – 53 Hz.
DC output voltage to the ODU
58V +2V/- 0V
AC connector
IEC-320-C8
Efficiency
Better than 85%, efficiency level ‘VI’
Over Current Protection
Hiccup current limiting, trip point set between 120% to 150%
of full load current
Hold up time
At least 10 milliseconds
Warning
Use the above PSU to only power up 450i and 450m products.
Содержание PMP 450 AP
Страница 51: ...Chapter 1 Configuration Quick link setup Page 1 23 ...
Страница 155: ...Chapter 1 Configuration Configuring security Page 1 127 ...
Страница 160: ...Chapter 1 Configuration Configuring security Page 1 132 Table 41 Security attributes 450 Platform Family BHM ...
Страница 163: ...Chapter 1 Configuration Configuring security Page 1 135 ...
Страница 164: ...Chapter 1 Configuration Configuring security Page 1 136 ...
Страница 169: ...Chapter 1 Configuration Configuring security Page 1 141 Table 43 Security attributes 450 Platform Family BHS ...
Страница 193: ...Chapter 1 Configuration Configuring radio parameters Page 1 165 ...
Страница 194: ...Chapter 1 Configuration Configuring radio parameters Page 1 166 ...
Страница 195: ...Chapter 1 Configuration Configuring radio parameters Page 1 167 ...
Страница 206: ...Chapter 1 Configuration Configuring radio parameters Page 1 178 ...
Страница 210: ...Chapter 1 Configuration Configuring radio parameters Page 1 182 ...
Страница 232: ...Chapter 1 Configuration Configuring radio parameters Page 1 204 Figure 27 Multicast scheduler statistics ...
Страница 305: ...Chapter 1 Configuration Configuring a RADIUS server Page 1 277 Table 89 Security tab attributes ...
Страница 342: ...Chapter 1 Configuration Configuring a RADIUS server Page 1 314 6 Finally press Save Changes and you are ready to use it ...
Страница 408: ...Chapter 3 Operation System information Page 3 8 Table 115 General Status page attributes PMP 450 AP ...
Страница 423: ...Chapter 3 Operation System information Page 3 23 Site Contact Site Location Time Updated and Location Code ...
Страница 636: ...Chapter 5 Troubleshooting Logs Page 5 16 Figure 95 SM Authorization log ...