Wind sensor is engineered to be a robust device
with minimal downtime. This new shape has been
designed for optimum water spillage which implies
lower probability of ice formation. Frost might
affect measurements if it blocks the wave path.
The box has IP68 rating (outdoors & underwater).
The input wires are protected by Transient Voltage
Suppression (TVS) diodes. Also, the instrument
body is built in Polyamide.
Every single unit is automatically calibrated on a
wind tunnel. A Q/C report for both module and
angle is generated and kept in our files. Standard
deviation is checked to warranty that each unit has
been calibrated to the highest standards.
4.
Installation
The installation of Davis Compatible Ultrasonic
wind sensor is very easy.
When you receive the Davis compatible ultrasonic
wind sensor, you have to put the included batteries
inside the box.
Remove the screws to open the box and insert them
in the battery holder in the correct position, after
that close the box with the screws.
Image 7. Battery placement.
2.
Press DONE repeatedly to scroll through the
screens until you come to the Wind Cup Size
screen.
3.
Press the + and - keys to toggle the sizes until
OTHER appears.
4.
Press and hold the DONE key to exit Setup
Mode and return to the Current Weather Screen.
Image 9. Davis Console.
Once you have mounted the wind sensor and box
in a suitable location, insert the RJ-11 end into the
cable access port of the ‘Sensor Interface’ and
firmly insert the RJ connector into the socket labeled
WIND.
Image 8. Connection to Sensor Interface.
To configure the console:
1.
Enter the Setup Mode by pressing DONE and
the – key at the same time.
Davis Compatible
User manual
Davis Compatible
User manual
4.2 Wind sensor and box connection
-
+