1 7 |
P a g e
deferral can be repeated up to three times.
PLEASE NOTE:
At any point after lamp expiration,
the water may be unsafe for consumption and should not be consumed without another form
of disinfection.
Lamp Replacement
After the lamp is expired, it must be replaced with the same part number as indicated on the
Maintenance Parts screen or on the label on the unit. With the system powered down, remove
and discard the lamp key from the controller. The replacement lamp is packaged with a lamp
key on the connector at the end of the lamp. Remove the key from the lamp and place it in the
controller. Refer to
Installation
, starting with step 11 (page 10) for instructions on installing the
new lamp.