AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS)
• All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 299 of 402
Query Format
SYSTem:AIO:OUTput[n]:GAIN:MINimum?
Description
Returns the minimum full-scale gain for the specified analog output.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:MIN?
-100000.00000
Query Format
SYSTem:AIO:OUTput[n]:UNITs?
Description
Returns the assigned unit for the specified analog output port.
Parameters
None
Returned Data Format
<cr>
Query Example
SYST:AIO:OUT2:UNIT?
Vrms
Query Format
SYSTem:AIO:OUTput[n]:VOLTage?
Description
Returns the voltage at the analog output port.
Parameters
None
Returned Data Format
<nr2>
Query Example
SYST:AIO:OUT2:VOLT?
7.2590
8.10.1.3
SYSTem:DIO:Input
Query Format
SYSTem:DIO:INput[n]?
Description
Queries status of Digital Input 1, 2 or 3. If I/O number is omitted, all
three input values are returned. n = 1, 2 or 3.
Parameters
none
Returned Data Format
<cr>
Parameter Format
<nr1>
Query Example
SYST:DIO:IN2?
0