LTR20231170
9/23/2023
www.calspas.com
29
Troubleshooting & Q and A
The Chill Spa has not gone down in temperture in over an hour:
The Chill Spa’s cooling system
may require additonal programing. removal of the left side exhaust panel will be necessary to confirm
the cooler is in the correct low temperture range. The use of a philips screwdriver or electric drill is
needed.
•
First set the chill spa to 39F, next remove the left exhaust side panel on the filter canister side.
• Remove the screws from the exhaust panel to access the water cooler.
•
Press the “SET” button on the cooler, once the display lights up, use the down arrow to lower its
maximum threshold to 39F
•
Once the water cooler screen reads 39F press “SET” again. This gives permission to the watercooler to
lower the water up to 39F. Close up the exhaust panel and close the insulated spa cover.
My Chill Spas water is cloudy:
The chill spa is set to constantly filter, although the filter will absorb
most of the contaminants this can occur once the water is saturated in contaminants or if the filter is dirty.
•
First inspect the filter, and clean thoroughly with a spa filter cleaner. Following the instructions of the
filter cleaning chemical as all procedures vary based on product used.
•
Change the water inside of the Chill Spa and refill using tapwater filtered through a carbon spa
prefilter. Follow your water treatment procedure using pages 14-19 as refrence. all water chemistry is
unique, further guidance can be found through your dealer or local pool/spa supply store.
66
Содержание PLATINUM Series
Страница 17: ...LTR20231170 9 23 2023 www calspas com 16...
Страница 18: ...LTR20231170 9 23 2023 www calspas com 17 13 13 11 13...
Страница 19: ...LTR20231170 9 23 2023 www calspas com 18...
Страница 22: ...LTR20231170 9 23 2023 www calspas com 21...
Страница 35: ...LTR20231170 9 23 2023 www calspas com 34...