Calsense ET2000 500 Series Скачать руководство пользователя страница 4

 
 

RAIN BUCKET SETUP

                                                                                     

 

®

 

m aking

         since 1986

 

water work

                                           

 

If a controller is not wired to a rain bucket, the RAIN 
BUCKET  SETUP  screen  will  only  have  one  setting 
(figure 8). This setting is described below: 

 

Let Rain Only Build Up to:

 This setting determines 

the  maximum  amount  of  rain  that  can  be  stored  in 
the  rain  table.  In  figure  8  the  controller  will  stop 
storing rain data in the rain table if the Maximum 24 
Hour Total reaches 1.50 inches of rain. 

 

Note:

  If  you  are  not  sharing  rain  data  using  the 

Calsense Command Center software, this setting will 
have no effect on irrigation. 

 

3. 

   Press the 

PLUS 

or 

MINUS 

key to 

                            change the setting.  
 

Set Use of Rain by Program:

 This section  

describes how to enable the use of rain in the  
ET2000 controller. Each program can be set  
individually to either use or not use rain to offset  
irrigation run times. From the RAIN BUCKET SETUP  
screen (Figure 8). 
 

4. 

   Press the 

SET USE OF RAIN BY 

 

                             PROGRAM

 Menu key. 

 
The USE OF RAIN BY PROGRAM screen  
(Figure 9). 
 

              PROG A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YES
              PROG B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YES

USE OF RAIN BY PROGRAM

        which    acts    to    cancel    irrigation.

Rain    causes    negative    hold-over    to     build

                          Allow    RAIN    on    the     following:

              DRIP 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES

              PROG C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YES
              PROG D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YES
              PROG E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YES
              DRIP 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . YES

 

Figure 9 

 

Here  you  will  have  the  option  of  enabling  or 
disabling the use of negative hold-over (rain) for any 
of  the  controller’s  seven  programs.  If  you  select 
YES,  Negative  hold-over  will  be  used  for  that 
program  to  reduce  irrigation  run  times.  If  you  select 
NO, rain will have no effect on irrigation run times for 
that program. If there is no rain bucket installed and 
you  are  not  sharing  rain  data  through  the  Calsense 
Command  Center  program,  these  settings  will  have 
no effect on irrigation.  

5. 

     Press the 

PLUS 

or 

MINUS

 key to  

                               change the setting.  

6. 

     Press the blue 

ARROW 

keys to 

                              move the cursor to the next entry.     

7. 

     Press the 

MAIN MENU 

key. 

 

The MAIN MENU screen (Figure 10). 

 

                 Setup                                                         Status

                         

                 Flow                                              Radio Remote

                 Weather                                                Reports

CALSENSE WATER MANAGEMENT SYSTEM

                 Programs & Stations                             Lights

 

 

Figure 10 

 

 

 RAIN SWITCH SETUP 

 

From the MAIN MENU screen. 

 

1. 

     Press the 

WEATHER

 Menu key  

                               (Figure 11). 
 

                 Setup                                                         Status

                         

                 Flow                                              Radio Remote

                 Weather                                                Reports

CALSENSE WATER MANAGEMENT SYSTEM

                 Programs & Stations                             Lights

 

 

Figure 11 

 
The WEATHER SETUP screen (Figure 12).  
 

 