51
only the Upper row of SFP’s are used for
both Primary and Secondary connections.
The Front Panel LEDs indicate the mode
of operation and which SFP’s are active.
ConfigPort
A Cat 5e connector on the rear of the unit
is used for factory setup and diagnostics.
FIGURE 2. H2 HUB - REAR VIEW
Power AC
Lights solid green when
internal PSU is active.
Power DC
Light solid green when
DC input valid. Flashes
when outside of range.
OK
Flashes green
heartbeat when
connected and running.
Fast flashing indicates
boot/establishing
comms.
Pri Sec RTR
Light solid green when
valid connections have
been made to the
Routers SFP ports.
Pri Sec 1-4
Light solid green when
valid connections have
been made to the
1 thru 4 I/O SFP ports.
Sec (Split)
Lights Yellow if Hub set
to Sec in Split Mode
STATUS LEDS
Height
< 1U - 40mm (1.6’)
Width
220mm (8.7’)
Depth
284mm (11.2’)
Weight
2.0kg (4.4lbs)
AC input power
100-240V AC, 0.30-0.13A RMS, 50/60Hz,
Supply current - 0.13A @ 240V, 0.26A @ 115V, 0.30A @ 100V
DC input power
10 - 30V DC, 15VA max.
Supply current - 1.25A @ 12V, 0.62A @ 24V
Power
dissipation
(heat)
15W when fed DC
19.5W when fed 100-240V AC
Operating
ambient air
temperature
0-40 C
SPECIFICATION
Pin 1
- V DC
Pin 4
+ V DC (10-30V)
DC INPUT CONNECTOR - 4 PIN XLR
• Unit connector is male, requiring a female termination on the connecting cable