Calrec Argo S Скачать руководство пользователя страница 12

12    ImPulse  

IP Audio Routing & Mixing System

Start Up Guide

5. POWER UP THE SURFACE & CREATE A NEW SHOW

FADER LAYOUT>NEW CHANNEL

Once the connections between the Impulse core and the Argo S or Argo Q console are made and the surface IP connections routed 
to the surface application container in the core, the surface can be powered up.  It is recommended that the Impulse cores are then 
restarted.  On restart, the console will boot up with the last loaded show  To ensure you are starting from a clean setup, before 
beginning configuration it is a good idea to create a new show

.

  Shows contain default settings for the console, including monitor 

patching, GPI patching & port labelling.  Shows also contain multiple user memories which save normal I/O patching, fader assignment 
and path parameter settings.  To create a new show, go to the 

Show

 

area highlighted (top left of the page shown below) and tap

 

on it.

  

This opens the Shows page and at the bottom is a ‘

+New

’ button which when pressed allows the user to create a new show.       

Choose the Calrec Default as the starting template, enter the details as prompted and click ‘

Create

’ to load the new, clean show onto 

the console. See the image below . The same page allows changes to the show to be saved,  as well as other shows to be loaded & 
saved, please refer to ‘

Argo Operator Manual (926-313).pdf.

The image shown below is accessed from the 

Fader Layout

 page which can be used to place Audio paths on to faders.  Here the    

user has selected a fader position (Layer 1-Fader 1A) and is about to add their first new path.  As can be seen from the New Path 
dialogue box there are 1122 mono channels available.  The user may then begin to configure the mixer with DSP paths, routing  etc, 
however we would recommend that the user completes the setup first.  See ”

13. Navigate the Console & Perform System Tests” 

on page 34 

for further information on Console operation and/or please refer to the 

Argo Operator Manual (926-313).pdf.

The DSP pack used here 
has

 1122 channels.

  Your 

Impulse system’s DSP Pack 
will be pre-installed to order

.

 

The Impulse Core has a 
number of DSP Pack sizes 
available, which can be 
installed in the DSP Module 
and each pack size can be 
used in conjunction with any 
Argo S or Argo Q surface. 
The DSP Pack options 
available are shown in a
detailed comparison table at 
the end of this guide.  See:-     

“DSP Pack Comparison” 
on page 38

SHOWS>NEW SHOW

Содержание Argo S

Страница 1: ...calrec com IP Audio Routing Mixing System for Argo S and Argo Q Consoles ARGO START UP GUIDE V1 0...

Страница 2: ...for International usage Calrec Audio Ltd reserve the right to change specifications without notice E O E The established policy of Calrec Audio Ltd is to seek improvements to the design specifications...

Страница 3: ...onfigure AoIP Core Router Ports AoIP I O Devices 17 Calrec Connect Login Instructions 18 10 Connecting the Audio Switch and AoIP Devices to the Core 28 11 Understanding Synchronisation 29 12 Examine a...

Страница 4: ...4 ImPulse IP Routing Mixing System...

Страница 5: ...calrec com IMPULSE START UP GUIDE...

Страница 6: ...lse is designed for use with a touch interface where possible Calrec recommends the use of a 1920x1080 touch screen monitor Please also confirm that all the parts listed on the system s packing list a...

Страница 7: ...ED on each core will flash Green to show that the system is running The Module and Fan OK LEDs should both be lit Green when running 4 Configure the Ethernet adapter in the PC with an unused IP addres...

Страница 8: ...page will be displayed as shown at the bottom of the next page 4 Set the system date time 5 You may also set new System and Core names here These names will be used by the system to identify and annou...

Страница 9: ...9 CONFIGURE HOME PAGE CONFIGURE GENERAL CONFIGURATION PAGE...

Страница 10: ...rs can click on the now routed icon again and apply save the change The rows to the right of the collapsible folders in the first column not to the right of the virtual adapters indicate routes that e...

Страница 11: ...as the IP link from the primary surface Ethernet switch to the primary Impulse core on SFP Port 3 of the control processor module See the blue connections in the image below This is repeated using the...

Страница 12: ...as prompted and click Create to load the new clean show onto the console See the image below The same page allows changes to the show to be saved as well as other shows to be loaded saved please refer...

Страница 13: ...ch is available at http ftp calrec com and access the information in the Type R area of the site using Account TypeR Password tYoarEdQ before you continue These switches are small scale devices genera...

Страница 14: ...ion in the Type R area of the site using Account TypeR Password tYoarEdQ The configuration files both allow the switch to operate in the 192 168 30 24 subnet for the Primary AoIP port address range an...

Страница 15: ...nario may not therefore be readily accessible to an operator or engineer s PC It is therefore recommended that these applications should be connected via either a Management or a Studio A subnet The M...

Страница 16: ...for Base Images Recovery Images and the release package for the Core itself which will have a calrec extension e g argo release_1 0 4 b55 calrec To install a newer software version 1 Navigate to the S...

Страница 17: ...right provides controls to view and configure the following for each of the router ports IP address Subnet mask Gateway optional Note the IP address and Subnet mask must be set with valid values The G...

Страница 18: ...r Web browser e g Chrome and browse to the address of the LAN port you are connected to e g 172 29 1 21 This will launch Connect which opens the Connect Login page shown below CALREC CONNECT LOGIN PAG...

Страница 19: ...c manually configured or DHCP dynamically allocated AoIP interface s MAC address AoIP interface connection speed AoIP interface TX use percentage AoIP interface RX use percentage Configure IP Settings...

Страница 20: ...ame e g Imp TX1 Transmitter interface e g AoIP 1 Pri Type of transmitter normally defined as a Multicast one to many type rather that a Unicast one to one type Number of channels in each transmitter e...

Страница 21: ...g L24 Packet time e g 125us Sample Rate e g 48000Hz Link Offset e g 2000us Receiver Settings Device When the user selects one of the available receivers or clicks on Add Receiver at the bottom of the...

Страница 22: ...ry box appears The user edits the label as required and clicks on Apply Lock Selection The user can click on the padlock symbol this will prevents any parameter changes from being made and will appear...

Страница 23: ...evice so that the matrix is easier to navigate There is also a Collapse All Expand All option for both transmitters receivers Adjacent to these are search entry boxes which allows the user to quickly...

Страница 24: ...ce e g AoIP 1 Pri Type of transmitter normally defined as a Multicast one to many type rather that a Unicast one to one type Number of channels in each transmitter e g 8 Codec used e g L24 Packet time...

Страница 25: ...s in each receiver e g 8 Codec used e g L24 Packet time e g 125us Sample Rate e g 48000Hz Link Offset e g 2000us Receiver Settings Core When the user selects one of the available receivers or clicks o...

Страница 26: ...n setting this will toggle the state of that function and will appear in Red when active Label Selection The user can click on the existing label and a label entry box appears The user edits the label...

Страница 27: ...nsmitter and receiver streams are networked together using a crosspoint matrix The user simply clicks on the crosspoint to connect audio streams between the Core and AoIP Devices The matrix shows wher...

Страница 28: ...Subnet in the Google Chrome address bar on and press enter to navigate to Connect Walk through all the steps in Section 9 of this guide and the system should then be ready to test Note Please refer t...

Страница 29: ...2 aware switches adjust the time stamps of PTP messages that they are forwarding on to factor in the delay caused by the switch the amount of time it takes to receive and forward on the message Best M...

Страница 30: ...ach of the interfaces will interact with the clock There are basic configuration settings and advanced configuration settings which are accessed from the Advanced settings button in the footer of the...

Страница 31: ...ill interact with the clock There are basic configuration settings and advanced configuration settings which are accessed from the Advanced settings button in the footer of the page Basic Synchronisat...

Страница 32: ...all Secondary AoIP traffic is on the 192 168 31 24 subnet There are 3 Modular I O Racks with AoIP interfaces and in the case of Modular I O rack 1 both AoIP Device interfaces have been used as the I...

Страница 33: ...outer Addresses Pri 192 168 30 211 213 Sec 192 168 31 211 213 Modular I O Addresses Pri 192 168 30 11 for 1A Sec 192 168 31 11 for 1B Pri 192 168 30 12 for 2A Sec 192 168 31 12 for 2B Modular I O Addr...

Страница 34: ...are fitted across the console as required CA6575 Wild Assign panel can be fitted in the Argo S Argo Q central control area for the Argo S one row of this panel type can be fitted or two rows for the l...

Страница 35: ...o it the B layer paths are accessed using the B button There is a further TFT display row shown at the bottom of the panel which shows both the A and B layer paths Mode Navigation Once the required pa...

Страница 36: ...valid This row of controls can be custom defined to display whatever control is required to be at hand from Show setup Customise panels PROCESSING MODE ROW Mode Row Sets The Mode Row Sets below show t...

Страница 37: ...then available to be sent out of the system The resultant output signals are sent via a Transmitter from the Impulse core into a Receiver in the I O box using the IO patching function The links to the...

Страница 38: ...pool OR 768 mono legs pool on Pack 7B Up to 4 outputs from 768 mono legs pool OR 512 mono legs pool on Pack 6B Up to 4 outputs from 768 mono legs pool OR 512 mono legs pool on Pack 5B Pack 5C Insert S...

Страница 39: ...and 6 12 18 db8v filters on Bands 1 6 Dynamics 2 x compress limiters 1 x expander gate ducker with sidechain source selection per Channel Group 2 band sidechain EQ per Channel 1 band sidechain EQ per...

Страница 40: ...Pack 2 Pack 2 Pack 2 Pack 2 None Pack 1 Pack 2 Pack 2 Pack 2 Pack 2 None Pack 2 Pack 2 Base Pack 3 Pack 3 Pack 3 Pack 3 Pack 3 None Pack 1 Pack 2 Pack 3 Pack 3 Pack 3 Pack 3 Pack 3 None Pack 1 Pack 2...

Страница 41: ...1 111 24 2 Router 1 2A 2B 192 168 30 112 24 192 168 31 112 24 3 Router 1 3A 3B 192 168 30 113 24 192 168 31 113 24 4 Router 1 4A 4B 192 168 30 114 24 192 168 31 114 24 5 Router 2 1A 1B 192 168 30 121...

Страница 42: ...1 1A 1B 192 168 30 211 24 192 168 31 211 24 2 Router 1 2A 2B 192 168 30 212 24 192 168 31 212 24 3 Router 1 3A 3B 192 168 30 213 24 192 168 31 213 24 4 Router 1 4A 4B 192 168 30 214 24 192 168 31 214...

Страница 43: ...O 2 1A 1B 192 168 30 13 24 192 168 31 13 24 4 AoIP Box Label 192 168 30 14 24 192 168 31 14 24 5 Mod I O 3 1A 1B 192 168 30 15 24 192 168 31 15 24 6 AoIP Box Label 192 168 30 16 24 192 168 31 16 24 7...

Страница 44: ...ainers that run the system and provide maintenance logs It s also used to configure the IP addresses of the Network Interface Controllers for the application containers manage the Remote Network inter...

Страница 45: ...45 USER NOTES...

Страница 46: ...926 321 Iss 2 Calrec Audio Ltd Nutclough Mill Hebden Bridge West Yorkshire England UK HX7 8EZ Tel 44 0 1422 842159 Fax 44 0 1422 845244 Email Enquiries calrec com calrec com...

Отзывы: