background image

1.0

 Circulation heaters for liquid service are designed for 

operation only while completely full with liquids. Never allow the 

heating elements to be exposed while energized or failure will 

result.

Use the heater only in liquids and at pressures 

for  which  it  was  designed  (unless  specifically 

designed for non-liquid applications). Normally 

copper sheath is recommended in water; steel 

or alloy sheath in oil; and the appropriate alloy 

sheath for heating gas and chemical solutions. 

Check factory for recommendations.

2.0

 Circulation heaters are welded pressure vessels with inlet 

and outlet connections to allow fluid/gas flow and heat transfer 

to a customer fluid.

3.0

 Where gasket is required, user must ensure that gasket 

surface is clean and dry before installing heater.

DO NOT insulate over the heater flange, stilted area 

and terminal enclosure.

4.0

 The terminals must be protected at all times from moisture 

or vapour. In hazardous locations, explosion-proof terminal 

housings must be used. In outdoor locations, moisture resistant 

housings are required. It is recommended to use a drip loop to 

prevent moisture from entering the terminal box via the wire. 

5.0

 Protect terminals of heating elements from drippings, 

condensation, fumes, spray or any other substance which could 

result in element contamination.

ISO 9001

ELECTRIC SHOCK HAZARD. All electric heating equipment installations must be performed

by qualified personnel in accordance with the local electrical codes and standards and must 

be effectively grounded to eliminate shock hazard.

FIRE/EXPLOSION HAZARD. Do not exceed the ratings of the flange as listed in ANSI B16.5. Do not 

operate the heater in the presence of combustible gases, vapours, dusts or fibres unless the heater is 

specifically marked for the hazardous location and heater operating temperature does not exceed the 

temperature code rating. Corrosion of the sheath could result in a ground fault which, depending upon 

the fluid being heated, could cause a fire or an explosion.

FIRE HAZARD. If a thermostat is provided, it is designed for temperature control service only. Since the

thermostat does not fail safe, it should not be used for temperature limiting duty. Wiring to this device is

the users responsibility.

Heaters are capable of developing high temperatures, therefore extreme care should be taken to:

a)   use explosion-proof terminal enclosures in hazardous locations;

b)   maintain distance between heater and combustible materials.

DESCRIPTION

Heaters with over temperature devices require 

specific installation orientation.

ELECTRIC SHOCK HAZARD. Disconnect all power 

before installing or servicing the heater. Failure to 

do so could result in personal injury and/or property 

damage. All maintenance and installation should 

be done by qualified personnel in compliance with 

local codes.

FIRE  OR  SHOCK  HAZARD:  Moisture  accumulation 

on  the  dielectric  material  of  the  elements  sheath, 

corrosion or overtemperature on the heaters could 

cause a fault to ground generating arcing and molten 

metal. Install proper ground fault protection to 

prevent personal injury or property damage.

Heaters  are  electrical  components,  designers 

are responsible for the proper integration to the 

electrical systems, including controls and backup 

safety devices.

6.0

 Provide adequate space for vertical or horizontal installation. 

With horizontal mounting, inlet and outlet must be directed 

upwards at 90° from the horizontal.

7.0 

Ensure that the circulation heater vessel is properly mounted 

on a solid steel or concrete base. For heater removal and 

maintenance purposes, user must allow sufficient clearance in 

the surrounding area of the circulation heater.

INSTALLATION

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR

TYPE EX – CIRCULATION HEATERS

Email: [email protected] 

www.ccithermal.com

Date of Issue: May 2013

Part No. MI416 Rev.10.01 

Printed in Canada

Содержание EXC

Страница 1: ...exceed the temperature code rating Corrosion of the sheath could result in a ground fault which depending upon the fluid being heated could cause a fire or an explosion FIRE HAZARD If a thermostat is provided it is designed for temperature control service only Since the thermostat does not fail safe it should not be used for temperature limiting duty Wiring to this device is the users responsibili...

Страница 2: ...htest possibility that the liquid level may fall below the elements a level control switch or overtemperature sensing device affixed to the uppermost heating element is required Check factory for recommendations 16 0 If the heater is installed in a pressurized system a safety relief valve must be used to prevent a hazardous pressure buildup 17 0 Heaters with explosion resistant terminal housings m...

Страница 3: ...ter design Rotation of the bundles should be avoided without consulting the manufacturer 36 0 If a heater element is damaged sheath rupture or electrical user must consult factory for further advice 37 0 Heater output can be verified by loop current draw or resistance check If heater is not operating properly user must verify resistance IR resistance to check integrity of heater elements 38 0 All ...

Страница 4: ...m the date of installation The Company neither assumes nor authorizes any person to assume for it any other obligation or liability in connection with the product s The Purchaser agrees that all warranty work required after the initial commissioning of the product will be provided only if the Company has been paid by the Purchaser in full accordance with the terms and conditions of the contract Th...

Страница 5: ... de fluide ou de gaz ainsi que le transfert thermique avec un fluide externe 3 0 Là où un joint d étanchéité est requis l utilisateur doit s assurer que la surface du joint est propre et sèche avant d installer le chauffeeau DÉFENSE d isoler par dessus la bride la zone surélevée et le boîtier de terminaison du thermoplongeur 4 0 Les bornes doivent être protégées à tout moment de l humidité et des ...

Страница 6: ...rectement serré c Un thermoplongeur pour les emplacements dangereux n est approuvé à l utilisation que si un dispositif homologué de contrôle du niveau du liquide et ou un dispositif homologué de haute limite de température sont employés pour mettre le thermoplongeur hors tension au cas où le niveau du liquide baisserait 18 0 Le montage du chauffe eau doit être effectué conformément aux spécificat...

Страница 7: ...rmétiques ne peut pas être résolu sur place Les valeurs normales de la résistance en présence de sceaux sont de 1000 MW ou plus 26 0 Vérifiez que tous les branchements sont serrés 27 0 Si un thermostat est fourni vérifiez qu il fonctionne correctement en le faisant passer par son cycle et en vérifiant la coupure du circuit 28 0 Effectuez un test IR avant la mise sous tension Vérifiez que les nivea...

Страница 8: ...faut d alignement des pièces Aucune garantie ne s applique à la finition de peinture excepté dans le cas de défauts de fabrication apparen ts dans les 30 jours à compter de la date d installation La Société n assume ni n autorise aucune personne à assumer en son nom toute autre obligation ou responsabilité en rapport avec le les produit s L Acheteur accepte que tout travail relatif à la garantie e...

Отзывы: