Junction Box
Before Installing
•
Failure to follow installation instructions, or misapplication, may
result in electrical shock, fire and/or personal injury hazard.
•
Installation must conform to all requirements of the National
Electrical Code (NEC) 426.23(B) (Fixed Outdoor Electric
Deicing and Snow-Melting Equipment) and any local codes or
ordinances. In countries other than the USA, follow the dictates
of the local electrical and building code.
•
The electrical source must conform to the heating units’ require-
ments (voltage and circuit amperage capacity) and overcurrent
protection device must incorporate a GFCI.
•
Connection of heating unit(s) should be performed by a
licensed electrician.
•
Do not cut, bend or otherwise alter the CalorIQue Heated Skid
Plate. Any alterations to the units may present a shock or fire
hazard.
•
Suitable overcurrent protection shall be provided by means of
circuit breaker or fuse. Overcurrent protection shall be of a type
indicated as being acceptable for branch circuit protection.
•
WARNING:
Ensure that adequate drainage is provided for
water runoff.
Tools & Materials
•
CalorIQue Heated Skid Plate.
See
Free Estimate Worksheet
(CM1012) for ordering details.
Typical heated skid plate. Your model may vary.
•
Standard Electrical Hand Tools.
•
Overcurrent Protection.
User / installer supplied. The circuit
breaker used with this sistem must have an overcurrent rating
of 30 amps and an integral GFCI rated for 30mA equipment
protection.
•
Electrical Conduit.
Rigid or flexible conduit meeting the
requirements of N.E.C. 426.23(B) of local code (e.g. carflex).
•
Electrical Wire.
Suitable wire for use within exterior conduit.
Three conductors must be available. Conductors may range
from #14-22 AWG, size based upon total ampacity connected.
•
Drill with Bits.
Bit must be rated for drilling into the material
onto which the skid plate(s) is being installed.
NOTE:
If using an anchoring method other than the supplied expan-
sion shields and stainless steel screws, follow the manufacturer’s
instructions for best results. In all preparation and installation steps
indicating use of the expansion shields and supplied 1/4” stainless
steel screws, replace with the anchor manufacturer’s instructions.
•
Construction Adhesive.
This adhesive must be water and heat
resistant.
Non-Skid Surface