Safety thermostat
press to reset
(red button)
FIG 3
MODEL
TTW33(7)/&
TTW30(7)A
TTW33(7)/&
TTW30(7)AX
TTW30(7)AP/&
TTW30(7)AXP
TTW55(7)/&
TTW60(7)A
TTW55(7)/&
TTW60(7)AX
TTW50(7)AP/&
TTW60(7)AXP
Dehumidification
L/hr
1.25
1.25
1.25
2.5
2.5
2.5
L/day
30
30
30
60
60
60
Total Heat to Air
Dehumidifier only
kW
1.9
1.9
1.9
3.5
3.5
3.5
Dehum & Resistance heater
kW
n/a
n/a
2.89
n/a
n/a
5.55
Resistance heater only
kW
n/a
n/a
2.0
n/a
n/a
4
Dehum & LPHW
kW
3.9
3.9
n/a
6.5
6.5
n/a
LPHW only
kW
3.0
3.0
n/a
5
5
n/a
Nominal Power Consumed
Fan only
kW
0.05
0.05
0.05
0.1
0.1
0.1
Dehum (Comp & Fan)
kW
0.75
0.75
0.75
1.2
1.2
1.2
Dehum & Heater
kW
n/a
n/a
2.75
n/a
n/a
5.2
Heater & Fan
kW
n/a
n/a
2.05
n/a
n/a
4.1
Supply
230V 50Hz
230V 50Hz
230V 50Hz
230V 50Hz
230V 50Hz
230V 50Hz
Fuse
A
10
20
20
13
13
32
Nominal Running Amps
A
3.4
3.4
11.7
5.6
5.6
22.3
Full Load Amps
A
4.4
4.4
12.7
7.5
7.5
24.2
Compressor LRA
A
15.8
15.8
15.8
30
30
30
Air Flow
m
3
/h
420
420
420
750
750
750
Noise Level @3m
dB/A
46
46
46
47
47
47
Water Flow Rate
L/min
5.0
5.0
n/a
5.0
5.0
n/a
Pressure Drop
m hd
1.1
1.1
n/a
1.8
1.8
n/a
LPHW Flow Rate
L/min
n/a
n/a
n/a
5.0
5.0
n/a
LPHW Pressure Drop
m hd
n/a
n/a
n/a
1.1
1.1
n/a
HERMETIC SYSTEM
Refrigerant Charge ‘A’ Dehumidifiers
kg R407c
0.5
0.4
0.5
0.75
0.8
0.75
Refrigerant Charge ‘AX’ Dehumidifiers
kg
0.5
0.5
0.45
0.75
0.8
0.8
R407c Global Warming Potential (GWP) 1774
NOTES:-
a) These performance figures are based on air @ 30ºC and 60% RH & pool water @ 28ºC, Boiler water at 80°C
b) Humidistat adjustable from 20% to 80%
c) Minimum air temperature on standard models 15°C and 0°C on defrost 'X' models
d) Reduced LPHW output when TTW operating is 1kW less on 33 model and 2kW less on 55 model
e) IP rating for all models is IP45
f) Maximum operating conditions air temp 35°C and 90% RH 1L/min = 0.22 gal/min
g) Maximum operating conditions for AP versions air temp 32°C and 62% RH
1mm Wg = 9.8 Pa
1m hd = 1.4 psi
1L/min = 0.22 gal/min