1005494 ISSUE 3

OWNER/INSTALLATION MANUAL

Model

IPT8ALX

IPT12ALX IPT16ALX IPT22ALX IPT12ALY IPT16ALY IPT22A/BLY IPT28ALY

Refrigerant 

charge 

R32 kg 0.6

0.9

1.1

2

0.9

1.2

2

2.7

Minimum 

area 

3.1

6.9

10.3

34.0

6.9

12.3

34.0

62.0

Notes

*Assumed worst case for access category: a - general access and location class: I - mechanical equipment in 

occupied space; both as defined in line with EN378-1 2016 section 5.1 table 4 and section 5.3

*Minimum Area is calculated in line with section C.2 on EN378-1 2016 (calculation C.2)

3�2 REFRIGERANT TYPE AND INSTALLED 
LOCATION

This heat pump contains R32, which is an 
environmentally friendly refrigerant with a GWP 
(Global Warming Potential) of 675. R32 has the safety 
in use classification of A2L, being low toxicity and 
lower flammability. In practical terms it is very difficult 
to ignite an A2L refrigerant, but this classification 
requires a risk assessment to be undertaken for the 
possibility of refrigerant being released by accident into 
an area connected to the heat pump, considering the 
application, location of components, and the installed 
refrigerant charge. This installation guidance can form 
the framework for such a risk assessment for the 
installation. 

All flammable refrigerants will not ignite if the 
concentration level in a room stays below their lower 
flammability limit (LFL). European standard EN378 
defines requirements to remain far below the lower 
flammable limit in case of accidental leakage. By 
choosing the location as dictated by EN378-1:2016 
the probability of forming a flammable atmosphere 
can be eliminated. Please refer to the minimum 
area for each product and the interpretation below 
regarding locations of heat pump and swimming pool. 
This information is provided as a guide only and does 
not supersede the regulations or health and safety 
requirements.

INTERPRETATION

Please refer to the installation situations below for how 
to apply the minimum area stated above. 

Pool outside and heat pump outside:  

Automatically meets the minimum area requirement 
because outside space is unlimited. 

Pool outside and heat pump inside a plant room:  

Automatically meets the minimum area requirement 
because the room must open to the outside for heat 
pump airflow and the outside space is unlimited.  

Pool inside and heat pump outside:  

The pool hall must exceed the minimum area 
requirement shown above.

Pool inside and heat pump inside a plant room, 
isolated from the pool hall:  

The pool hall must exceed the minimum area 
requirement shown above. 

Pool inside and heat pump inside a plant room, 
ventilated to the pool hall:  

The pool hall and plant room combined must exceed 
the minimum area requirement shown above. 

Содержание IPT 12 ALY

Страница 1: ...I PAC I PAC inverter heat pumps IPT 8 12 16 22 28 Owner Installation Manual 1005494 Issue 3...

Страница 2: ...s This appliance can be used by children from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision...

Страница 3: ...PPLY 17 3 8 CONNECTING THE HEAT PUMP TO THE POWER SUPPLY 18 3 9 POOL PUMP SYNCHRONISATION TERMINALS P1 AND P2 19 3 10 INSTALLING THE OPTIONAL REMOTE CONTROLLER 20 4 0 USING YOUR HEAT PUMP 22 4 1 THE K...

Страница 4: ...e heat pump Please read and follow all safety advice The refrigerant used in this heat pump is R32 This refrigerant is environmentally friendly but safety instructions must be strictly adhered to The...

Страница 5: ...e following location requirements must be fulfilled The heat pump must be kept away from sources of fire or naked flames The heat pump must be installed operated and stored where the floor area is lar...

Страница 6: ...orms can damage electronic equipment Ideally the heat pump should be switched off at the mains HEAT PUMP MALFUNCTION WARNING Isolate heat pump electrically and wait 3 minutes before removing panels or...

Страница 7: ...nts may not contain an odour Appliance shall be installed operated and stored in a room with a floor area larger than Xm2 where X is the minimum area shown in section 3 2 and section 8 0 The heat pump...

Страница 8: ...t Do not lift the heat pump by the water inlet or outlet connections If this is done the titanium heat exchanger inside the heat pump could be damaged 2 2 ACCESSORIES These accessories are provided wi...

Страница 9: ...E 3 2 3 OPTIONAL ACCESSORIES The following items are additional accessories available for purchase Rubber mounting kit Pack of 4 mounts Remote controller kit for indoor installation 10m extension cabl...

Страница 10: ...ication Stable inverter control system 2 5 OPERATING CONDITIONS AND RANGE Air temperature operating range I PAC IPT X models 5 43 C I PAC IPT Y models 10 43 C Water temperature setting range Heating 1...

Страница 11: ...e solid and fixed securely Brackets must be corrosion proof Do not block inlet or outlet grilles The heat pump absorbs energy from the air drawn through it To function effectively the heat pump must h...

Страница 12: ...free areas to provide air flow to and from heat pumps when installed in an enclosed area or where required to pass air through a wall etc Ensure the heat pump is sealed against the wall so the outlet...

Страница 13: ...494 ISSUE 3 350 cm Swimming pool or spa To comply with safety regulations regarding electrical installations in wet areas the heat pump must be installed at least 350cm away from the edge of the pool...

Страница 14: ...ill not ignite if the concentration level in a room stays below their lower flammability limit LFL European standard EN378 defines requirements to remain far below the lower flammable limit in case of...

Страница 15: ...Non return valve Sanitiser or chemical dosing device If fitted Aux heater If fitted Filter Pump To waste for winterising drain down 100mm Condensate water to waste Spare port for winterising flushing...

Страница 16: ...onditions 3 5 INITIAL CHECKS Start the filtration pump before the heat pump is turned on and turn off the heat pump before the filtration pump It is recommended to turn off the heat pump prior to back...

Страница 17: ...filters pump strainer boxes heat exchangers steps and handrails It is highly recommended that bonding be retrofitted to existing pools which may not be protected by this system All electrical work to...

Страница 18: ...ugh cable entry points in machine Isolator which disconnects all poles fitted within 2m and in line of sight of the heat pump L3 N Fuses MCB Earthed Power Supply 400V 50Hz L3 N P1 P2 Power terminals P...

Страница 19: ...rough the heat pump to sample the water temperature The default sampling time interval is 1 hour If the measured temperature is more than 1 C from the set temperature the point heat pump will continue...

Страница 20: ...0m away Take the lid off the I PAC to gain access to the existing controller Remove the front cover Disconnect the plug from the socket on the back of the controller as shown Remove the bulkhead conne...

Страница 21: ...mperature on the remote controller to slightly higher than the pool water The I PAC should run to heat the pool immediately if the pump synchronisation is not in use or at the next sampling period if...

Страница 22: ...n Off 2 Wi Fi Setting Lock Unlock and Heat Mode 1 Lock Unlock Screen 2 Heating mode 18 40 C 3 Cooling mode 12 30 C 4 Auto mode 12 40 C Speed Mode 1 Boost 2 Whisper Up Down Temperature Setting The butt...

Страница 23: ...oose Boost mode for initial heating f Wi Fi When the screen is on press for 3 seconds after flashes enter Wi Fi connection Connect Wi Fi on mobile phone and input password then control equipment by Wi...

Страница 24: ...E APP a APP Download b Account registration Register Login with Existing Acount 1 Register by mobile or E mail 2 Account Registra on 1 APP Download Android please download from iOS please download fro...

Страница 25: ...nects to the Wi Fi successfully the light will come on Add Family Enter Family name You can change room seettings anytime Set location 3 Create Family Please set family name and choose the room of dev...

Страница 26: ...26 1005494 ISSUE 3 OWNER INSTALLATION MANUAL Confirm Indicator Rapidly Blink Xiaomi_abc Confirm Add Device Pool Heat Pump 2 Click Add Device and then follow instruc ons to pair device...

Страница 27: ...27 1005494 ISSUE 3 Done...

Страница 28: ...ng temperature 1 For heat pump with Hea ng func on only Select Boost Whisper Mode The se ng temperature On O The current swimming pool water temperature Indicates the mode Boost or Whisper mode Timer...

Страница 29: ...The weather forecast is just for reference App is subject to updating without notice Boost PoolTherm Setting 20 c c 24 c F A er pairing if your family members also want to control the device Please le...

Страница 30: ...NER INSTALLATION MANUAL 4 4 USING THE OPTIONAL REMOTE CONTROLLER 4 5 THE KEY PAD Symbol Function Power On Off Heating Cooling Auto mode Press to start Boost mode Press to start Whisper mode Temperatur...

Страница 31: ...and light will turn on Press to start Whisper mode and light will turn on Default mode is Boost Please choose Boost mode for initial heating c Defrosting 1 Automatic defrosting When machine is defros...

Страница 32: ...with detailed information and your model number Don t try to repair it yourself 5 0 TESTING Check that the fan air inlets and outlets are not obstructed It is prohibited to install refrigeration pipe...

Страница 33: ...ly 4 E6 Low water flow indicated by more than 10 C difference in inlet and outlet temperature Check water flow and pool pump 5 Eb Ambient temperature is out of range either lower than 5 C 10 C Y versi...

Страница 34: ...as return temp sensor failure 13 P6 Cooling coil pipe temp sensor failure 14 P7 Ambient temp sensor failure 15 P8 Cooling plate sensor failure 16 P9 Current sensor failure 17 PA Restart memory failure...

Страница 35: ...d by authorised technicians It is illegal to allow refrigerant gases to escape to air Do not attempt to work on the equipment by yourself Improper operation may cause danger Requirements for service p...

Страница 36: ...3 21 0 69 4 25 Rated input current A 1 38 7 58 1 82 10 8 2 60 14 61 3 16 19 32 Maximum input current A 9 5 12 5 19 5 20 Rated RCD type F mA 30 30 30 30 Rated Fuse aM MCB type C A 16 16 25 25 Sound pre...

Страница 37: ...2 28 0 41 3 15 0 48 3 91 Rated input current A 1 17 9 91 1 78 13 69 2 08 17 00 Maximum input current A 13 5 17 20 Rated RCD type F mA 30 30 30 Rated Fuse aM MCB type C A 20 25 25 Sound pressure level...

Страница 38: ...wer kW 0 41 3 15 0 48 3 91 0 64 5 20 Rated input current A 0 59 4 56 0 69 5 66 0 92 7 53 Maximum input current A 5 8 7 9 5 Rated RCD type B mA 30 30 30 Rated Fuse aM MCB type C A 10 10 16 Sound pressu...

Страница 39: ...88 429 1084 640 74 948 107 A B C D E F G H J IPT12 ALY 334 590 318 359 954 340 74 648 107 IPT16 ALY 404 590 388 429 954 460 74 755 107 IPT16 BLY 404 590 388 429 954 460 74 755 107 IPT22 ALY 404 720 38...

Страница 40: ...630 565 50 IPT16 ALX 478 465 349 315 675 666 50 IPT22 ALX 645 630 462 405 799 861 50 K L M N P Q R IPT12 ALY 478 465 300 349 743 566 50 IPT16 ALY 587 540 370 349 731 667 50 IPT16 BLY 587 540 370 349...

Страница 41: ...provide frost protection To eliminate corrosion problems To inhibit electrical components 1 Switch off electrical supply to heat pump 2 Remove external fuses and keep in safe place away from heat pump...

Страница 42: ...nd duct pressure are outside the specified limits 9 The air flow to and from the machine is outside the specified limits If in doubt or if advice is required please contact the Dantherm Group UK Servi...

Страница 43: ...43 1005494 ISSUE 3 12 0 DECLARATION OF CONFORMITY...

Страница 44: ...Dantherm Ltd Unit 12 Galliford Road Maldon CM9 4XD United Kingdom 44 0 1621 856 611 sales uk dantherm com Calorex is a brand of danthermgroup co uk...

Отзывы: