Model  

CASCADE- 6TC

Serial Number
Draw off capacity 

 18 Litres  

Heat-up Time 
(Full capacity - first switch 
on)                                            

 48 Minutes  

Max flow rate from tap
 (Boiler full)

4.5 Litres / Minute

Average flow rate from tap 
(During 18 litre Draw off)

2.8 Litres / Minute  

Voltage

220 - 240 V ac    50 - 60 Hz

Power rating 

6kW (max) single phase

PLEASE ENTER  SERIAL NUMBER FOR FUTURE 
REFERENCE

Note:  All measurements are approximate.

 

PLEASE CONTACT OUR SERVICE DEPARTMENT FOR ASSISTANCE

 

Calomax Limited, Lupton Avenue, Leeds LS9 7DD

 

Tel: 0113 249 6681

 

Fax: 0113 235 0358

 

e-mail: [email protected]

Содержание CASCADE-6TC

Страница 1: ...D SERVICING INSTRUCTIONS Calomax Limited Lupton Avenue Leeds LS9 7DD Tel 0113 249 6681 Fax 0113 235 0358 E mail service calomax co uk www calomax co uk Please read these instructions carefully before...

Страница 2: ...GENERAL NOTES 8 CLEANING 8 SPARE PARTS 9 10 EXPLODED DIAGRAM 12 13 SERVICE INSTRUCTIONS 11 ACCESSORIES 16 17 WIRING DIAGRAM 18 TROUBLE SHOOTING 19 WARRANTY 20 PRODUCT SPECIFICATION 24 CHECK LIST Befo...

Страница 3: ...alve must be fitted to the supply BEFORE CONNECTING THE SUPPLY PIPE MUST BE THOROUGHLY FLUSHED OUT TO ENSURE THAT FOREIGN MATTER DOES NOT BLOCK OR ENTER THE SOLENOID VALVE The boiler must be connected...

Страница 4: ...ing cycle and water is drawn from the tap water will be replaced in short cycles small amount of water and then heat The solenoid and elements will never be on at the same time unless the boiler is sw...

Страница 5: ...his booklet All de scaling and servicing must be performed by a suitably qualified engineer GENERAL NOTES GENERAL OPERATION Avoid using any abrasive materials Wiping the outer casing with a damp cloth...

Страница 6: ...as over filled due to debris trapped in the solenoid valve The debris can be removed by drawing plenty of water from the dispense tap causing the solenoid valve to operate and flush out the obstructio...

Страница 7: ...uired are not identified please contact Calomax Limited Includes nuts washers etc Exploded parts view To be read in conjunction with the spare parts list Wrapper not shown for clarity 1 2 3 4 5 6 9 10...

Страница 8: ...uld be switched off allowed to cool completely and the level sensors cleaned thoroughly as stated above before reseting the elements and switching the boiler back on If in doubt protect the elements b...

Страница 9: ...RIAC LIGHT PCB ELEMENT 3kW THERMISTOR ASSEMBLY KIT SOLENOID VALVE BODY LID GASKET WATER INLET HOSE LEVEL PROBES KIT PRESSURE RELIEF GROMMET 1 2 3 4 8 7 6 5 9 10 11 12 15 14 13 CBTCW X2 X2 16 SPRSK SIN...

Страница 10: ...RANGE WHITE BLACK 0 75mm 2092 GREY 0 75mm 2114 N L Y G 2 5mm 2063 Y G 2 5mm 2147 COLD WATER INLET SOLENOID VALVE Left ELEMENT with THERMAL CUTOUT HIGH NORMAL LOW LEVEL SENSORS THERMISTOR EARTH ON BODY...

Страница 11: ...he warranty offered These include Incorrect installation High Low water pressure Incorrect voltage supply Accidental damage Limescale build up The last item can be a particular problem for water dispe...

Страница 12: ...Page 22 Page 23 SERVICE HISTORY AND NOTES SERVICE HISTORY AND NOTES...

Страница 13: ...Average flow rate from tap During 18 litre Draw off 2 8 Litres Minute Voltage 220 240 V ac 50 60 Hz Power rating 6kW max single phase PLEASE ENTER SERIAL NUMBER FOR FUTURE REFERENCE Note All measureme...

Отзывы: