
Calix ODC-80 Installation Guide
13
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© 2001-2003 Calix. All Rights Reserved.
Installation Prerequisites
Site requirements
You will need a concrete pad with conduit entry for subscriber cables, AC power, and
ground to support the Calix ODC-80.
Install a ground rod, or similar grounding device, with a maximum resistance to ground of
20 ohms near the pad site.
See the "Calix ODC-80 Pour-In-Place Template Instructions" if you plan to construct the
pad using a Calix template.
Footprint dimensions
Recommended pad dimensions are 148 inches by 96 inches; 5 1/2 inches deep. Pad depth
may vary depending on site and environmental conditions.
These pad dimensions allow for full door clearance around the cabinet.
Footprint clearance
Содержание ODC-10
Страница 1: ...Calix ODC 80 Installation Guide July 2003 Part 220 00029 Rev 11...
Страница 2: ......
Страница 6: ......
Страница 7: ...1 Chapter Before You Begin Installing the ODC 80...
Страница 8: ......
Страница 23: ...2 Chapter Placing the ODC 80 on a Pad...
Страница 24: ......
Страница 30: ......
Страница 31: ...3 Chapter Installing Power Subscriber Cables and Equipment...
Страница 32: ......
Страница 74: ......
Страница 75: ...4 Chapter Maintaining and Troubleshooting the ODC 80...
Страница 76: ......
Страница 80: ......
Страница 92: ......
Страница 103: ...5 Chapter Reference...
Страница 104: ......
Страница 106: ......